Potentiometric titration of chloride in plant tissue extracts using the chloride ion electrode1
作者:
R. L. LaCroix,
D. R. Keeney,
L. M. Walsh,
期刊:
Communications in Soil Science and Plant Analysis
(Taylor Available online 1970)
卷期:
Volume 1,
issue 1
页码: 1-6
ISSN:0010-3624
年代: 1970
DOI:10.1080/00103627009366233
出版商: Taylor & Francis Group
关键词: analytical potentiometry;potentiometric titrimetry;chloride;plant tissue;specific ion electrodes
数据来源: Taylor
摘要:
Use of the chloride specific ion electrode to determine chloride in plants was evaluted. Direct potentiometric determination of chloride by the electrode resulted in unreproducible and extremely high chloride values. However, use of this electrode to indicate the end point in titration of the tissue‐extract mixture with AgNO3gave results nearly identical to those obtained by the Mohr procedure. The potentiometric titration procedure developed was found to be a rapid, simple and accurate method of determining the chloride concentration in plants.
点击下载:
PDF (192KB)
返 回