Residual strength of reinforced concrete columns exposed to fire
作者:
Chien‐Hung Lin,
Shun‐Tyan Chen,
Tze‐Lee Hwang,
期刊:
Journal of the Chinese Institute of Engineers
(Taylor Available online 1989)
卷期:
Volume 12,
issue 5
页码: 557-566
ISSN:0253-3839
年代: 1989
DOI:10.1080/02533839.1989.9677195
出版商: Taylor & Francis Group
关键词: reinforced concrete;column;residual strength;fire
数据来源: Taylor
摘要:
Several methods were employed to evaluate the residual strength of reinforced concrete columns exposed to different durations of fire. These methods included the analytical method, ultrasonic tests, hammer tests and load tests. Fifty columns were involved in the tests. Calculated temperatures and residual strengths of the test columns were compared with those measured. Comparisons were also made between results from load tests and those from nondestructive tests. The results showed that using analytical procedures is acceptable while the nondestructive test methods are accurate only for shorter durations of fire.