首页   按字顺浏览 期刊浏览 卷期浏览 Mechanical factors in electrode‐induced osteogenesis
Mechanical factors in electrode‐induced osteogenesis

 

作者: J. A. Spadaro,   D. E. Mino,   S. E. Chase,   F. W. Werner,   D. G. Murray,  

 

期刊: Journal of Orthopaedic Research  (WILEY Available online 1986)
卷期: Volume 4, issue 1  

页码: 37-44

 

ISSN:0736-0266

 

年代: 1986

 

DOI:10.1002/jor.1100040105

 

出版商: Wiley Subscription Services, Inc., A Wiley Company

 

关键词: Bone formation;Implant micromotion;Electrodes;Medullary canal;Mechanical stimulus

 

数据来源: WILEY

 

摘要:

AbstractPrevious experiments have suggested that mechanical activity of electrode implants may contribute to the observed bone formation that has been attributed to the electrical currents. This was tested by implanting movable and stationary wires in the medullary canal of the rabbit femora or tibiae. The moving implants uniformly showed significant medullary bone formation at the wire, whereas the stationary ones did not. This bone persisted for as long as 8 weeks and was mostly resorbed by 12 weeks as the implants became fixed. The new trabecular bone closely resembled that typically seen at electrically active implants. Implant motion may have a more important role in electrically induced osteogenesis than previously thought.

 