Determination of transition metals in the primary water of pressurized water reactors by inductively coupled plasma mass spectrometry

 

作者: Rolf J. Rosenberg,  

 

期刊: Journal of Analytical Atomic Spectrometry  (RSC Available online 1994)
卷期: Volume 9, issue 6  

页码: 713-717

 

ISSN:0267-9477

 

年代: 1994

 

DOI:10.1039/JA9940900713

 

出版商: RSC

 

数据来源: RSC

 

摘要:

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY JUNE 1994 VOL. 9 71 3 Determination of Transition Metals in the Primary Water of Pressurized Water Reactors by Inductively Coupled Plasma Mass Spectrometry Rolf J. Rosenberg and Riitta Zilliacus Technical Research Centre of Finland VTT Chemical Technology P. 0. Box 1404 FIN-02044 VTT Finland Pentti K. G. Manninen Health and Environmental Inspection Centre Control and Research Laboratory Niemenkatu 73 FIN-I5210 LAHTI Finland A method for the determination of the transition metals Fe Mn Ni and Co in the primary water of pressurized water reactors (PWRs) is described and applied to the analysis of water at the Loviisa power plants. Samples are collected via the standard sampling line or an isokinetic line. There is no difference in the results obtained.The water is filtered through a 0.45 pm membrane filter under oxygen-free conditions to separate the soluble and insoluble fractions. The transition metals are concentrated and separated from boric acid using cation chromatography. A quantitative yield is obtained and concentration factors of up to 500 are used. The samples are analysed using inductively coupled plasma mass spectrometry. The detection limits obtained are Fe 2 Mn 0.2 Ni 0.2 and Co 0.02 ng I-' when a 1 I sample is used. Keywords Inductively coupled plasma mass spectrometry; transition metals; primary water; pressurized water reactor The radiation field build-up on the primary circuit components in nuclear power plants is of concern because of the exposure of the workers to radiation. Most of the radiation is caused by activation products from transition metals mostly 6oCo from Co 5sC0 from Ni and 54Mn from Fe.In order to study the physico-chemical mechanisms of the production and trans- port of the radionuclides it is necessary to know the concen- trations of the source metals in the primary water. The concentration of Fe must also be known in order to understand the corrosion and corrosion product transport phenomena. Usually the soluble and insoluble metals are determined separ- ately in order to obtain information on the solubilities. Two different stages of reactor operations are normally studied. During full power the transition metal concentrations are very low and the variation moderate. Therefore the sampling frequency can be one sample per month or less.During shut- down the solubilities increase and fast transients in the trans- ition metal concentrations can be observed. Therefore shut- downs and sometimes the return to full power are followed with high sampling frequency up to one sample per hour over 3-4 days. The analysis is not without problems. The sampling is complicated by the need to reduce the pressure and tempera- ture the latter because the pH changes which affects the solubility.' The samples are transported through tens of metres of steel pipes. The problems concerning representative sampling have been extensively investigated and discussed in a number of papers.'-6 It has been shown that absorption and desorption phenomena affect the transport of radionuclides and transition metals in the pipelines in a way which is not yet fully understood.However it has also been shown that under appropriate conditions analytical results behave logically in a way that enables a comparison between different reactors and different years of the same reactor to be made. Bridle and co-~orkers'*~ introduced a so-called isokinetic sampling system in which the pressure drop is effected with a 50 m long capillary tube instead of the normal valves and heat exchangers. They indicate that the isokinetic sampling line gives a more represen- tative sample than the standard sampling line because the water flow is smooth without variations in flow rate. However experimental data verifying this statement have not been presented. Svoboda et a1.2 compared an isokinetic sampling line with a standard one.They did not observe any differences in the concentrations of Fe Ni and Co. The samples should be filtered before the water has been in contact with air. This prevents the oxidation of Fe which would drastically decrease its solubility. Usually 0.45 pm mem- brane filters are used although part of the insoluble material seems to be in colloidal form with particle sizes much below that. The lowest Co concentrations found in the insoluble fraction during full power are below 1 ng 1-l.' Therefore several tens or even hundreds of litres of water might be filtered for a sample. The lowest soluble Ni concentrations during full power are a few tens of ng 1-' the lowest Co concentrations a few ng 1-l.' Therefore most analytical techniques in use require a precon- centration step.Two methods have been used. Ion-exchange filters such as Acropor SA 6404 Whatman SA2 and Sumimoto Chemical Expapier F-2 have been ~ s e d . ~ ~ . ' ~ These have the benefits that fairly high sampling rates can be maintained 50-150mlmin-' and that they can be used in combination with a particle filter and an anion filter. The reported capacities can be 0.5 mmol per filter although experiment has shown the practical capacity to be one tenth of this.2 In combination with ion chromatographs preconcentration columns can be conveniently used.'*7 They have capacities of up to 0.45 mequiv. One drawback is the low sampling speed 1-2 ml min- '. Two different types have been used in this work. They are the Dionex MetPac CC-1 and Waters Guard Pak.A variety of analytical techniques have been used for the determination of the transition metals. The only technique capable of determining Co during full-power conditions in most reactors without preconcentration is ~oltammetry."-~~ The reported detection limits are 1-2 ng 1-' for Co and 8 ng 1-1 for Ni. All other methods require a degree of preconcentration if low concentrations are to be detected. Ion chromatography has been widely applied in European power plants mainly by the Winfrith Group in the UK.',7,14-17 Using preconcentration of a 1 1 sample a detection limit of 0.5 ng 1-1 of Co has been reported.' Atomic absorption spectrometry can in principle be used after preconcentration from a very large sample.2 The detection limit could be significantly improved by using electro- thermal vaporization but no actual results from determinations of low levels of Co have been reported.A few determinations using X-ray fl~orescence~,~ and flow injection te~hniques''~~~ have also been reported the latter without any details on the method. Neutron activation analyses have also been used but714 JOURNAL OF ANA.LYTICAL ATOMIC SPECTROMETRY JUNE 1994 VOL. 9 the detection limits are low requiring a considerable precon- centration.2 Inductively coupled plasma mass spectrometry (ICP-MS) is a very sensitive method for analysis of water but to date very few applications on the analysis of nuclear power plant (NPP) waters have been reported. There are a few references to work on loop tests and boiling water reactor (BWR) analysis but these contain very few The present paper describes the development of methods for sampling preconcentration and ICP-MS determination of soluble and insoluble Fe Mn Ni and Co in the primary water of a pressurized water reactor (PWR) results for the determi- nation of these metals in the primary water of the Loviisa 1 power plant during the refuelling shut-down in 1992 and Loviisa 1 and Loviisa 2 during full power in 1993 are presented.Only a few results are presented to show the applicability of the method. The full results together with a discussion will be published later. Experimental Sampling In old reactors the sampling lines are fixed and cannot be changed. In the Loviisa 1 NPP an isokinetic sampling by-line had also been installed and this was compared with the standard line.The basic principle of sampling is to have a steady continu- ous flow through the sampling line in order to avoid transients which change the physico-chemical parameters. Another prin- ciple is to prevent the oxidation of Fe before the filtering and the preconcentration steps. In the present work a 0.45 pm membrane filter was used mainly in order to facilitate a comparison with literature data. It was realized however that a smaller pore size filter should be used in order to separate all the smaller particles. This will be investigated in future work. During the shut-down of the Loviisa 1 plant (18-21 July 1992) 0.5-1 1 samples were filtered in closed Nalgene filter holders equipped with 11 receiver containers.Nitrogen gas was passed through the system to prevent contact with air. Part of each of the filtered samples was poured into 1OOml acid washed polyethylene bottles which were immediately frozen. The frozen samples were stored for up to 3 months before analysis. Most of the samples were taken from the purification circuit before the ion-exchange columns. This sampling line had an isokinetic by-line installed in 1989.7 Samples were taken both from the standard outlet and the isokinetic line. The isokinetic line was opened 9 d before the actual sampling started. The flow rate was 35 ml min-I. The standard sampling line was opened 5 d before the sampling started. The flow rate was about 1 1 min-I. During the shut-down of the Loviisa 2 plant (11-15 September 1992) sampling was made from the corresponding purification circuit but only using the standard sampling line which was opened 3 d before the sampling started. A Millipore filter holder was connected directly to the sampling line to prevent the access of air.A 101 bottle was used for measure- ment of the volume of the filtered water. From 10 to 201 samples were filtered. The water was preconcentrated immedi- ately after filtering but the preconcentration was made from water that had been poured from one container into another. Therefore it had been in contact with air. The above experiences resulted in the final sampling arrange- ment shown in Fig. 1. Both the filtering and the preconcen- tration are performed in a closed system which prevents the access of air. This system was used for the analysis of the water of the Loviisa 2 reactor during full power in February 1993.The continuous sampling flow was 1.6 1 min-'. About 30 1 of water were filtered. Preconcentration The reason for the preconcentration is two-fold. Firstly the samples have to be concentrated in order to improve the Sample in Q Sample to Three-way valve Peristaltic pump +- Vo I LI me me as u re m e nt flask Bottle Eluant and regeneration solution Fig. 1 a PWR Principles of the arrangement for sampling primary water of detection limits and thus the accuracy of the analysis. Secondly the high boric acid concentrations up to 12 g 1-' prevent the direct injection of the water into the ICP-MS system which is equipped with a normal nebulizer. Therefore the boric acid has to be removed.Two different preconcentration columns were tested. These were the Waters Guard Pak which is packed with a porous polystyrene gel with sulfonate functional groups and the Dionex MetPac CC-1 which contains a macroporous iminodiacetate chelating resin. The preconcen- tration procedures shown in Table 1 are those used although not necessarily the optimal ones. The reason for choosing these schedules was partly to be able to run the two preconcentration columns in parallel. The Waters column was tested in the laboratory using simulated reactor water containing 12 g 1-' of boric acid 6mg1-I of NH 2mg1-I of KOH 50ngml-I of Fe 13 ng ml-' of Mn 106 ng ml-' of Ni and 0.3 ng ml-I of Co. Different amounts of the water were run through the column which was eluted according to Table 1.The metal concen- trations in the 1Oml elution fraction were determined by ICP-MS to establish the yield. The capacity was determined by running 500ml of the water through the column in order to exceed the capacity significantly. The column was then eluted and the concentrations determined by ICP-MS. Because only preconcentration with the Waters Guard Pak was tested in the laboratory the behaviour of the Dionex MetPac CC-1 was tested by comparing it with the Waters Guard Pak. This was done by preconcentrating every second sample of the Loviisa 1 samples with each column. The Loviisa 1 samples were left to thaw in the refrigerator after which they were preconcentrated according to the above scheme. In the Loviisa 2 sampling a number of parallel samples were preconcentrated with each column immediately after sampling.The blank of the MetPac CC-1 column and the reagents was measured by regenerating the column with 20ml of the Table 1 Preconcentration scheme for the Waters Guard Pak and the Dionex MetPac CC-1. During the shut-downs 50-100 ml samples were preconcentrated while during full power 1-2 1 samples were used ~ Step Dionex MetPac CC-1 Waters Guard Pak Adsorption 100-2000 ml water 100 ml water Elution 2 ml 1 moll-' HNO 10 mlO.1 moll-' HNO Regeneration 10 ml 0.1 moll-' HNO 8 ml 1 mol I-' HNO 10 ml buffer 2 mol I-' NH,Ac pH 5.5JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY JUNE 1994 VOL. 9 71 5 buffer solution cleaning the column with 10 ml of de-ionized water and eluting with 2 ml of 1 mol 1-' HNO,.Determination of the Transition Metals by ICP-MS The samples were analysed with a VG PlasmaQuad PQ2-t ICP-MS. The operating parameters are shown in Table 2. The samples are radioactive although the activity is low being mostly at a level permissible for free handling. In order to avoid unneccessary releases of radioactive material the gaseous effluents were filtered with an absolute filter and the liquid effluents collected and stored as radioactive waste. The samples taken during shut-down were diluted with water to 5-10m1 and run with the sample changer with the parameters shown in Table 2 using a 30 s dual mode counting time. The scanning mode was used. The samples taken during full power were diluted to 5 ml. The samples were run using the sample changer by injecting a 250 pl sample followed by a 1% HNO washing solution.After a 45 s delay when the sample reached the analyser a 10 s measurement in the peak jumping pulse counting mode was started. The best masses to be used proved to be 55Mn 56Fe 58Ni and 59C0. Calibration curves were produced from solutions of 1.0-50 ng ml-I prepared by dissolving pure metals in HN03. The measurements were checked by analysing suitably diluted SPEX multi-element plasma standard ICP-MS solutions. Blanks were prepared from the corresponding elution solutions. When using the normal Ni sampling cone the blanks caused by contamination from the analyser and the argon ions varied somewhat but were of the order of Fe 180 Ni 3-10 Mn 0.3 and Co 0.04-0.1 ng ml - '. Through using a sampler made from A1 at the work-shop of the Reactor Laboratory the Ni blank was lowered to 0.5 ng ml-'.Also the Fe blank was decreased to 35 ng ml-l. In future the skimmer will also be made of A1 and the solutions and other parts of the analyser checked once more to decrease the blanks further. The A1 sampler seems to be much more resistant to the plasma than the Ni sampler probably because of its excellent heat and electrical conductivity. The column was shown to give a considerable blank when left standing for a few hours both after the regeneration and elution. Therefore the column has to be cleaned by elution with 1 moll- ' HNO before it is taken into use. The purity of the reagents must be controlled. The similarity of the Ni and Co results and the great difference in concentration caused a suspicion of a Ni inter- ference on the Co peak.Therefore pure Ni solutions were analysed for Co in order to detect any overlapping. The reproducibility of the ICP-MS measurements were investigated by analysing the same samples several times at different time intervals. The long-term stability of the concen- trated samples which were stored in a refrigerator and the long-term stability of the ICP-MS instrumentation was investi- gated by analysing a set of samples twice with an interval of 3 months. The first time was in October 1992 and the second time in January 1993. The samples on the filters were first dissolved in HN03 but the dissolution proved to be incomplete. Later a procedure was adopted where the filter was soaked in 1 ml of 1 + 1 HCl with gentle heating.The sample was then diluted with water for the ICP-MS measurements. Table 2 Operating parameters for ICP-MS R.f. power Cooling gas Aerosol carrier gas Sample introduction Measurement time Dwell time Range 1.35 kW 14 1 min-' 0.8 1 min-' 1 ml min-' 10-30 s per pulse counting mode 0.64 ms 50-65 ?TI/Z Results and Discussion Sampling and Storage of Samples A comparison of the soluble metal concentrations obtained from samples taken through the standard sampling device (A) and the isokinetic sampling line (B) is shown in Fig. 2. Although there is some variation in the results there is no indication that there would be a systematic difference between the two sampling lines. This confirms the results of Svoboda et aL2 that the isokinetic sampling line is no better than the normal one.The results also indicate that no loss or contamination occurred during the 3 months' storage of the samples. Preconcentration The results of the recovery tests are shown in Table 3. The recoveries are satisfactory provided the concentrations are well below the capacity of the column. The results for Fe are poor probably because it occurs in colloidal form or is hydrolysed. In the real preconcentration situation the non-filterable Fe is kept in solution because of the lack of oxygen which would oxidize it. The results of the comparison of the two different column types are shown in Fig. 3. It can be seen that in general the results for all elements agree well although the Dionex results are systematically somewhat higher.The reason for this is not known. Although the Waters column contains metal parts there is no sign of contamination. The low concentrations also agree well. In practical use the Dionex columns have been 80 - (a) B 60 - 40 - 20 - 0 80 i 60 40 20 0 0.15 0.12 0.09 0.06 0.03 B 0 5 10 15 20 25 Time/h Fig. 2 Metal concentrations of samples obtained from the Loviisa 1 shut-down using A standard and B isokinetic sampling lines in parallel for (u) Mn; (b) Ni; and (c) Co. Time scale in hours from a reference time716 JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY JUNE 1994 VOL. 9 Table 3 Results of the concentrations tests with a Waters Guard Pak column the yield of the elements and the total capacity of the column Parameter Fe Mn Ni c o Yield from 10 ml of water (YO) 44 100 99 100 Yield from 20 ml of water (%) 34 100 100 100 Yield from 50 ml of water (YO) 7 89 97 97 Capacit y/ng 560 1210 9800 27 Corresponds to x ml of water 10 94 92 90 more reliable the capillary connections of the Waters columns tending to be clogged at times.ICP-MS Determinations The results of the interference of Ni on Co when an area of 0.6m/z is used for integration are shown in Table4. This means that 1 ng of Ni corresponds to 7 x lo-' ng of Co. A Ni to Co ratio of 14000 would cause a positive error of 10% in the Co result. In the results presented the greatest Ni to Co ratio is 400. When a 0.4 m/z integration area is used no effect can be detected. The reproducibility of the ICP-MS results is shown in Table 5. The results indicate that the long-term stability of the concentrated samples is good.The detection limits for the different metals depend mainly on the variation of the blanks. Using the aluminium sampler and the 10 s measurement technique detection limits can be as good as 1 ng ml-' for Fe 0.1 ng ml-' for Mn 0.1 ng ml-' for Ni and 0.010 ng ml-' for Co. With concentration of a 11 sample to 2 ml the sample primary water detection limits are correspondingly Fe 2 Mn 0.2 Ni 0.2 and Co 0.02ng1-I. Naturally accurate results can only be obtained with concen- trations at ten times these levels but even then the limits are clearly below what is normally found in these samples. The concentrations of the soluble metal ions during the refuelling shut-downs of Loviisa 1 in 1992 are shown in Fig. 4. Some values of the concentrations in the primary water of the Loviisa 1 and Loviisa 2 power plants in 1993 during full power are shown in Table 6.The concentrations of the elements show similar behaviour to results reported from other reac- t o r ~ . ' ~ ~ * ~ ~ ' ~ The TV04 samples the water in the purification circuit before the ion exchangers and TV08 after the water has passed the ion exchangers. The results for soluble Ni and 60 (a) A V 15 45 75 105 Table 4 Effects of Ni on the concentration of Co Ni/ng ml- Co/ng ml- ' 100 200 400 0.008 0.01 1 0.025 Table 5 Transition metal concentrations (ng ml-') of samples taken during the Loviisa 2 (L02) shut-down. Parallel measurements made with an interval of 3 months Sample LO216 L02/10 LO2113 L02/16 L02/19 L02/41 L02/44 LO2147 LO2150 LO2153 LO2156 LO2160 Fe 0.11 1.7 4.5 1.2 11.5 14 29 18.5 32 35 30 - Fe 0.21 1.5 4 0.45 13.6 13.7 28 12 44 22 19 - Mn 0.91 2 2.6 3.6 2.3 3.9 4.3 7.7 11.1 30 28 23 Mn 0.89 2.2 3 3.7 2.2 3.7 3.7 5.4 7.5 18 18 14 Ni Ni 0.13 0.13 0.36 0.43 0.71 0.87 1.3 1.4 0.75 0.83 3.6 3.8 3.5 3.2 7.8 6.2 7.5 6 27 25 43 52 41 49 c o 0.0045 0.007 0.009 0.017 0.01 0.019 0.02 0.032 0.023 0.069 0.11 0.11 c o 0.004 0.006 0.01 1 0.017 0.008 0.018 0.017 0.024 0.014 0.048 0.074 0.076 Co are of the same order of magnitude as the full power values for other reactors as reported in the l i t e r a t ~ r e .~ * ~ * ~ * ~ ~ ~ ' ~ * ~ ~ The range of results is as follows Ni 10-300 ngl-' with a few values above 500 ng 1-'; and Co 0.4-10 pg 1-' with a few values considerably above these.The work is continuing with further development of the sampling and analysis methods. More results together with a discussion of the significance of the results will be published later. Conclusions A new method has been developed that enables the sampling and determination of Fe Mn Ni and Co in the primary water of PWRs using ICP-MS. The soluble and insoluble fractions are analysed separately. The fast transients in the concen- trations of Mn Ni and Co occuring during shut-down can be followed. This fact together with the detected decrease of the transition metal concentrations in the water going through the purification system seems to indicate that the sampling and 0.20 0.15 0.10 0.05 0 15 45 75 105 Tirne/h Fig. 3 Comparison of the results obtained by preconcentration of parallel samples during the Loviisa 2 shut-down using the columns A Dionex MetPac CC-1 and B Waters Guard Pak for (a) Fe; (b) Ni; (c) Mn; and (d) CoJOURNAL OF ANALYTICAL ATOMIC SPECTROM 0.5 (C) I 00 06 12 18 00 06 12 18 00 06 12 18 00 12 18 Timeth Fig.4 Soluble transition metal concentrations (a) Mn (b) Ni and (c) Co in the primary water of the Loviisa 1 power plant during the 1992 re-fuelling shut-down. Time in hours from noon the day before shut-down (July 18 1992) to July 21 1992. The reactor reached sub- criticality on July 18 1993 at 6.46 hours Table 6 Soluble transition metals (in ng 1-I) in the Loviisa 1 and Loviisa 2 primary water during full power in 1993 ;TRY JUNE 1994 VOL. 9 71 7 Sampling date 22-23 June 1993 23-24 June 1993 Loviisa I TV04 Loviisa 2 TV04 3-4 February 1993 4-5 February 1993 11-12 February 1993 16-17 February 1993 28-29 April 1993 29-30 April 1993 Loviisa 2 TVO8 Fe Mn 460 54 270 48 2300 112 2400 103 2000 101 1700 71 1260 81 73 10 Ni 17 8 171 171 169 110 117 22 c o 0.9 0.8 7.8 3.8 3.7 2.7 3.4 0.55 analysis is representative enabling the follow-up of concen- tration gradients occuring in different parts of the primary circuit.The detection limits are low enough to enable the determination of the elements during full power in all reactors. This study was commissioned by the Finnish Centre for Nuclear Safety (STUK) and has been funded by the Imatran Voima Power Company (IVO). Seija Suksi (STUK) Magnus Halin Thomas Buddas Risto Jarnstrom and Vesa Talvitie (IVO) Marjo Lauren and Jaana Rantanen (Reactor Laboratory) assisted in the performance of the work.1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 References Bridle D. A. Brown G. R. and Johnson P. A. V. AEA Technology Winfrith UK unpublished results. Svoboda R. Ziffermayer G. Romanelli S. Kaufmann W. Sozzi L and Schaefer M. E. Water Chemistry of Nuclear Reactor Systems 3 British Nuclear Energy Society (BNES) London 1983 p. 331. Polley M. V. and Anderson P.-O. Water Chemistry of Nuclear Reactor Systems 5 British Nuclear Energy Society (BNES) London 1989 p. 71. Larger N. R. Mead S. Nichols J. L. Patel N. M. Lawson D. and Becket N. A. Water Chemistry of Nuclear Reactor Systems 5 British Nuclear Energy Society (BNES) London 1989 p. 63. Large N. R. Harper A. Ashmore C. B. Beckett N.A. Nichols J. L. Johnson P. A. V Bridle D. A. and Cake P. Proceedings of the 1991 JAIF Conference on Water Chemistry in Nuclear Power Plants Fukui City April 22-25 1991 p. 672. Eley C. D. Thomas D. M. Libaert D. F. and Cattle R. A. Water Chemistry of Nuclear Reactor Systems 6 British Nuclear Energy Society (BNES) London 1992 p. 224. Bridle D. A. Brown G. R. Cake P. and Staunton G. M. AEA Technology Winfrith UK Report AEA-TRS-2043 1991. Bridle D. A. and Cake P. Water Chemistry of Nuclear Reactor Systems 6 British Nuclear Energy Society (BNES) London 1992 p. 324. Raymond A. De Murcia A. and Dhainaut S. Anal. Chim. Acta 1987 195 265. Takiguchi H. Morishita S. Kasahara K. Fukuda F. Sakai K. and Meguro Y. Proceedings of the International Conference on Water Chemistry in Nuclear Power Plants Japan Atomic Industrial Forum Tokyo Japan 1988 p.168. Torrance K. and Gatford C. Talanta 1985 32 273. Torrance K. and Gatford C. Analyst 1986 111 359. Ruhle W. VGB Kraftwerkstechnik 1985 65 252. Amey M. D. H. and Brown G. R. AEE Winfrith Report Bird E. J. Bridle D. A. Amey M. D. H. Roofthoof R. De Ranter K. and Philippe R. Water Chemistry for Nuclear Reactor Systems 4 British Nuclear Energy Society (BNES) London 1986 p. 21. Bridle D. A. Brown G. R. and Hamacher P. presented at VGB-Konferenz Chemie in Kraftwerk Essen Germany October 1989 p. 39. Bridle D. A. Cake P. Symons W. J. and Katona J. AEA Technology Winfrith UK internal report. Abe K. Mizusaki H. Ohta H. Hemmi Y. Umehara R. Ooshima S. Fukuda F and Kashara K. Proceedings of the 1991 JAIF International Conference on Water Chemistry in Nuclear Power Plants Japan Atomic Industrial Forum Fukui City Japan 1991 p. 599. Miyazaki S. Ohshima S. and Ojima Z Proceedings ofthe 1991 JAIF International Conference on Water Chemistry in Nuclear Power Plants Japan Atomic Industrial Forum Fukui City Japan 1991 p. 584. Monahan J. Mead A. P. and Lawson D. Water chemistry of Nuclear Reactor Systems 4 British Nuclear Energy Society (BNES) London 1986 p. 95. Buckley D. Water Chemistry of Nuclear Reactor Systems 6 British Nuclear Energy Society (BNES) London 1992 p. 199. Schenker E. Francioni W. and Degueldre C. Water Chemistry of Nuclear Reactor Systems 6 British Nuclear Energy Society (BNES) London 1992 p. 133. AEEW-R2044 1986. Paper 3/06147G Received October 14 1993 Accepted February 25 1994

 

点击下载:  PDF (750KB)



返 回