Measurements on a dc volume H−multicusp ion source for TRIUMF
作者:
K. R. Kendall,
M. McDonald,
D. R. Mosscrop,
P. W. Schmor,
D. Yuan,
G. Dammertz,
B. Piosczyk,
M. Olivo,
期刊:
Review of Scientific Instruments
(AIP Available online 1986)
卷期:
Volume 57,
issue 7
页码: 1277-1281
ISSN:0034-6748
年代: 1986
DOI:10.1063/1.1138642
出版商: AIP
数据来源: AIP
摘要:
We describe a dc volume H−source, employing multicusp plasma confinement, which has been constructed for use with the TRIUMF cyclotron. An extracted H−current density of 12 mA/cm2has been obtained. Beam emittance and brightness have been measured as a function of current density and beam fraction. Beam brightness values for normalized beam emittances of the order of 0.2 &pgr;mm mrad at 81% beam fraction are typically 10 mA/(mm mrad)2[equivalent rmsB=223 mA/(mm mrad)2].