首页   按字顺浏览 期刊浏览 卷期浏览 Suppression of odd harmonic components in a cyclotron beam pick‐up signal by mea...
Suppression of odd harmonic components in a cyclotron beam pick‐up signal by means of sampling

 

作者: J. F. P. Marchand,   F. Schutte,   H. L. Hagedoorn,  

 

期刊: Review of Scientific Instruments  (AIP Available online 1974)
卷期: Volume 45, issue 3  

页码: 361-363

 

ISSN:0034-6748

 

年代: 1974

 

DOI:10.1063/1.1686629

 

出版商: AIP

 

数据来源: AIP

 

摘要:

The current and the phase angle of the internal beam with respect to the accelerating voltage of the Eindhoven University of Technology AVF cyclotron are measured using a number of electrostatic induction pick‐up probes. Data handling is by means of sampling, correlating, and a CAMAC system. On the hf signal is superimposed a very strong first (fundamental) harmonic signal induced by the accelerating voltage. Therefore, the second harmonic component of the probe signal is used. Furthermore, all odd harmonic components of the signal are suppressed by using a special sampling technique. For the first harmonic component the suppression is about 60 dB.

 

点击下载:  PDF (170KB)



返 回