首页   按字顺浏览 期刊浏览 卷期浏览 Wideband multiplier correlator
Wideband multiplier correlator

 

作者: L.R.Allen,   R.H.Frater,  

 

期刊: Proceedings of the Institution of Electrical Engineers  (IET Available online 1970)
卷期: Volume 117, issue 8  

页码: 1603-1608

 

年代: 1970

 

DOI:10.1049/piee.1970.0284

 

出版商: IEE

 

数据来源: IET

 

摘要:

Apparatus to measure the correlation between two wideband (10–100MHz) noise signals has been developed for the stellar intensity interferometer at the Narrabri observatory. This instrument is used to measure the angular diameters of stars in the range 0.01–0.0001″ of arc, with an accuracy within about 5%. To achieve this precision with the low signal/noise ratio of an intensity interferometer, it is necessary to integrate and average the data for periods up to 100h, which may involve observations spread over several weeks. The paper describes the novel techniques which have been used to obtain the necessary efficiency and stability in the electronic correlator.

 

点击下载:  PDF (890KB)