首页   按字顺浏览 期刊浏览 卷期浏览 Power losses in a conducting sheet with bar domains. II. Losses due to switching
Power losses in a conducting sheet with bar domains. II. Losses due to switching

 

作者: B. E. Lorenz,   R. L. Coren,  

 

期刊: Journal of Applied Physics  (AIP Available online 1982)
卷期: Volume 53, issue 3  

页码: 2698-2700

 

ISSN:0021-8979

 

年代: 1982

 

DOI:10.1063/1.330981

 

出版商: AIP

 

数据来源: AIP

 

摘要:

We consider a model of a magnetic sample with distribution of Barkhausen switch sites which reverse their moments at a constant rate. Switching is considered in the case that reversal is induced by the incidence of a domain wall. The induced current distribution J of symmetrically placed regions has already been determined. The loss calculation involves summing J2over switching regions in the plane of the moving wall, and summing as the wall traverses a full cycle. Averaging techniques are employed and the expected loss over unit volume, per cycle is found, due solely to the Barkhausen regions. This is the classic static or ’’hysteresis’’ loss. In a later report the analysis is extended to determine the full losses.

 