The insertion of an inductance in the condenser arm of an intermittent glow discharge circuit was found to affect the characteristics of the oscillations. The voltage‐frequency curve was noticeably altered, the wave form of the voltage across the condenser became sinusoidal and other new wave forms were introduced. Within a certain range, the frequency of oscillation was practically independent of the voltage, resistance or tube characteristics. Various applications are suggested.