首页   按字顺浏览 期刊浏览 卷期浏览 Calibration of the X‐ray ring quadrupoles, BPMs, and orbit correctors using the ...
Calibration of the X‐ray ring quadrupoles, BPMs, and orbit correctors using the measured orbit response matrix

 

作者: J. Safranek,   M. Lee,  

 

期刊: AIP Conference Proceedings  (AIP Available online 1994)
卷期: Volume 315, issue 1  

页码: 128-136

 

ISSN:0094-243X

 

年代: 1994

 

DOI:10.1063/1.46761

 

出版商: AIP

 

数据来源: AIP

 

摘要:

The quadrupole strengths, beam position monitor (BPM) gains, and orbit correction magnet strengths were adjusted in a computer model of the NSLS X‐Ray ring in order to best fit the model orbit response matrix to the measured matrix. The model matrix was fit to the 4320 data points in the measured matrix with an rms difference of only 2 to 3 microns, which is due primarily to noise in the BPM measurements. The strengths of the 56 individual quadrupoles in the X‐Ray ring were determined to an accuracy of about 0.2%. The BPM and orbit corrector calibrations were also accurately determined. A thorough analysis of both random and systematic errors is included. © 1994 American Institute of Physics

 

点击下载:  PDF (407KB)



返 回