首页   按字顺浏览 期刊浏览 卷期浏览 Single Sample Anodic Stripping Voltammetry of Mercury and Other Heavy Metal Ions Using ...
Single Sample Anodic Stripping Voltammetry of Mercury and Other Heavy Metal Ions Using a Glassy Carbon Electrode and Integrated Circuit Electronics

 

作者: DonaldR. Kendall,  

 

期刊: Analytical Letters  (Taylor Available online 1972)
卷期: Volume 5, issue 12  

页码: 867-873

 

ISSN:0003-2719

 

年代: 1972

 

DOI:10.1080/00032717208062151

 

出版商: Taylor & Francis Group

 

关键词: Stripping voltammetry;mercury;heavy metals;water analysis;integrated circuits

 

数据来源: Taylor

 

摘要:

A two step anodic stripping voltammetry of a single sample of water which has been made 0.1Nin HC104, is useful for simultaneously detecting Hg+2, Zn+2, Cd+2, Pb+2, Cu+2, Co+2and Ni+2. In the first step mercury is determined by deposition onto a bare glassy carbon electrode (GCE) with subsequent stripping, and in the second step the remainder of the metal ions above are sought by deposition onto a mercury plated GCE and subsequent stripping. With a deposition time of 72.82 min the detection sensitivity varies from about 0.2 ppb for cobalt to about 10 ppb for zinc. Silver, tin and chloride were found to be interferences in the detection of some of the metal ions.

 