The influence of beam type on the back reflection of ultrasonic beams from a liquid–solid interface
作者:
Andrew N. Norris,
期刊:
The Journal of the Acoustical Society of America
(AIP Available online 1984)
卷期:
Volume 76,
issue 2
页码: 629-631
ISSN:0001-4966
年代: 1984
DOI:10.1121/1.391162
出版商: Acoustical Society of America
关键词: solid−fluid interfaces;ultrasonic waves;backscattering
数据来源: AIP
摘要:
We consider the phenomenon of back reflection of a beam of ultrasound from a liquid–solid interface. We show that the magnitude of the back reflection depends critically upon the profile of the incident beam. The beam profile is first related to the excitation field at the plane of the transducer. Different beams are considered by changing the field at the transducer. We show that a purely Gaussian profile gives no back reflection. Other beam profiles with less severe decay away from the beam center can produce an effect of the same order as observed experimentally. We present an example of such a beam.
点击下载:
PDF
(375KB)
返 回