首页   按字顺浏览 期刊浏览 卷期浏览 Evaluation of the sterility of thermodilution room‐temperature injectate prepara...
Evaluation of the sterility of thermodilution room‐temperature injectate preparations

 

作者: KATHLEEN BURKE,   ELAINE LARSON,   LINDA MACIOROWSKI,   DIANE ADLER,  

 

期刊: Critical Care Medicine  (OVID Available online 1986)
卷期: Volume 14, issue 5  

页码: 503-504

 

ISSN:0090-3493

 

年代: 1986

 

出版商: OVID

 

数据来源: OVID

 

摘要:

This study assessed the bacteriologic safety of room-temperature injectate used for cardiac output measurement in a surgical ICU, and compared its cost/benefit relationship to that of prefilled packaged syringes and a closed-loop injectate system. Ninety-five samples of injectate were obtained at four time intervals from staff-prepared syringes, and cultured for microbiologic growth. About 29% (27/95) of samples yielded bacterial growth, ranging from two colony-forming units to those too numerous to count. All positive samples contained skin flora, including coagulase-negative staphylococci and coryneforms. Additionally, five plates contained colonies of Gram-negative bacteria. Extended storage time increased the risk of contamination: 16.2% were contaminated within the first 24 h, whereas 45% were contaminated when stored for more than 72 h. Switching to a closed injectate system significantly (p< .001) decreased the incidence of contamination by 1.2%, and also allowed a cost savings of $1.52/patient.

 

点击下载:  PDF (146KB)



返 回