首页   按字顺浏览 期刊浏览 卷期浏览 A High Resolution Nuclear Spectrometer
A High Resolution Nuclear Spectrometer

 

作者: Lawrence M. Langer,   C. Sharp Cook,  

 

期刊: Review of Scientific Instruments  (AIP Available online 1948)
卷期: Volume 19, issue 4  

页码: 257-262

 

ISSN:0034-6748

 

年代: 1948

 

DOI:10.1063/1.1741239

 

出版商: AIP

 

数据来源: AIP

 

摘要:

A magnetic spectrometer for the measurement of beta‐ and gamma‐ray energies has been constructed. By using an inhomogeneous field varying radially in the proper manner, it is possible to bring electrons which leave the source with an extremely wide spread in angle to essentially a perfect focus in 180°. It has thus been possible to use a large mean radius of curvature of 40 cm in order to obtain high resolution combined with a reasonable transmission of about 0.1 percent of the total solid angle. Under operating conditions, with a 0.4‐cm wide source, the full width at half maximum for an internal conversion line is 0.5 percent. Scattering and background effects are negligible.

 

点击下载:  PDF (398KB)