Employing Heterocyclic Dihydropolyazines for Amperometric Glucose Sensing
作者:
J. Kulys,
A. Palaima,
G. Urbelis,
期刊:
Analytical Letters
(Taylor Available online 1998)
卷期:
Volume 31,
issue 4
页码: 569-584
ISSN:0003-2719
年代: 1998
DOI:10.1080/00032719808001862
出版商: Taylor & Francis Group
关键词: Biosensor;Glucose oxidase;Graphite;Amperometry;Mediator 5;10-Dihydro-5;10-dimethylphenazine;1,4-Dihydro-1,3,4,6-tetraphenyl-s-tetrazine
数据来源: Taylor
摘要:
Glucose sensors containing heterocyclic dihydropolyazines: 5,10-dihydro-5,10-dimethylphenazine (DHDMP) or 1,4-dihydro-1,3,4,6-tetraphenyl-s-tetrazine (DHTPT) as mediators and glucose oxidase adsorbed on graphite rods generated an anodic current at 0.10 (DHDMP) and 0.55 (DHTPT) V vs SCE in the presence of glucose at pH 7. The potential of the sensors correlated with the electrochemical conversion of the mediators. Under aerobic conditions calibration graphs for the sensors showed a slightly sigmoidal character with half-saturation concentrations of 58 ± 6 and 43 ± 9 mM glucose and Hill coefficients of 1.68 ± 0.07 and 1.88 ± 0.16, respectively. The calibration curves were hyperbolic over the whole glucose concentration in deaerated buffer solution and the sensitivities were 0.47 and 0.18 μA/mM for DHDMP and DHTPT containing electrodes, respectively. The sensor response increased in weakly alkaline medium. Calculated values of pKa, (7.0 ± 0.2), were similar for both type electrodes, were independent of buffer solution components and correlated with glucose oxidase reactivity (pKa= 7.3 ± 0.05) in homogeneous solution.