Capacitance voltage divider for high‐voltage pulse measurement
作者:
W. A. Edson,
G. N. Oetzel,
期刊:
Review of Scientific Instruments
(AIP Available online 1981)
卷期:
Volume 52,
issue 4
页码: 604-606
ISSN:0034-6748
年代: 1981
DOI:10.1063/1.1136644
出版商: AIP
数据来源: AIP
摘要:
A circuit capable of dividing 250 kV pulses by a ratio of 100,000 has been built and tested. It permits use of standard oscilloscopes to view high‐speed transients that have components between 200 kHz and 200 MHz. The design is an adaptation of the guard ring principle, commonly used in electrostatic measurements.