首页   按字顺浏览 期刊浏览 卷期浏览 Capacitance voltage divider for high‐voltage pulse measurement
Capacitance voltage divider for high‐voltage pulse measurement

 

作者: W. A. Edson,   G. N. Oetzel,  

 

期刊: Review of Scientific Instruments  (AIP Available online 1981)
卷期: Volume 52, issue 4  

页码: 604-606

 

ISSN:0034-6748

 

年代: 1981

 

DOI:10.1063/1.1136644

 

出版商: AIP

 

数据来源: AIP

 

摘要:

A circuit capable of dividing 250 kV pulses by a ratio of 100,000 has been built and tested. It permits use of standard oscilloscopes to view high‐speed transients that have components between 200 kHz and 200 MHz. The design is an adaptation of the guard ring principle, commonly used in electrostatic measurements.

 