When electron beams are to be rapidly and accurately deflected by magnetic means, there are some cases in which the deflection yoke is surrounded by a conducting magnetic tube. Eddy currents are set up in the tube which result in time‐dependent positional errors. A simplified treatment of the problem shows how the positional errors can be reduced by means of compensating coil pairs or hybridized saddle‐toroidal yokes.