Early Results of Unconventional Pedicular Screw‐Plate FixationsThe Indian Experience
作者:
SHEKHAR,
BHOJRAJ SHREEDHAR,
期刊:
Spine
(OVID Available online 1991)
卷期:
Volume 16,
issue 10
页码: 1192-1196
ISSN:0362-2436
年代: 1991
出版商: OVID
关键词: developing countries;spinal instability;unconventional pedicular fixation;posterior lumbar interbody fusion;posterolateral fusion;fusion time
数据来源: OVID
摘要:
Twenty cases of spinal plating with locally made simple bone plates, done between a period from August 1988 to March 1990 at our Institute, are reported here. The main indication for plating was spinal instability, either existent or created following decompression or an osteotomy. These cases included spondylolisthesis, spondylolysis, traumatic fracture-dislocations, lumber canal stenosis, tumors, prolapsed intervertebral discs, and seronegative spondyloarthropathy. Posterior lumbar interbody in 13 cases and posterolateral fusion in five was added to the spinal plating. Fusion rate was 100% at the end of 5 months. There was no incidence of implant breakage, and one case of screw loosening. One case had screw-related radiculopathy that subsequently settled. In all, 80 screws were used, out of which 75 had optimal and five suboptimal placements. In spite of limited facilities available in the developing countries, satisfactory results could be expected with this unconventional and simple technique.