Measuring the Performance of Anesthetic Depth Indicators

 

作者: Warren Smith,   Robert Dutton,   Ty Smith,  

 

期刊: Anesthesiology  (OVID Available online 1996)
卷期: Volume 84, issue 1  

页码: 38-51

 

ISSN:0003-3022

 

年代: 1996

 

出版商: OVID

 

关键词: Monitoring: depth of anesthesia;Statistics: discrimination accuracy; measure of association; predictive performance

 

数据来源: OVID

 

摘要:

BackgroundAn appropriate measure of performance is needed to identify anesthetic depth indicators that are promising for use in clinical monitoring. To avoid misleading results, the measure must take into account both desired indicator performance and the nature of available performance data. Ideally, anesthetic depth indicator value should correlate perfectly with anesthetic depth along a lighter‐deeper anesthesia continuum. Experimentally, however, a candidate anesthetic depth indicator is judged against a "gold standard" indicator that provides only quantal observations of anesthetic depth. The standard anesthetic depth indicator is the patient's response to a specified stimulus. The resulting observed anesthetic depth scale may consist only of patient "response" versus "no response," or it may have multiple levels. The measurement scales for both the candidate anesthetic depth indicator and observed anesthetic depth are no more than ordinal; that is, only the relative rankings of values on these scales are meaningful.MethodsCriteria were established for a measure of anesthetic depth indicator performance and the performance measure that best met these criteria was found.ResultsThe performance measure recommended by the authors is prediction probability PK, a rescaled variant of Kim's dy*symbol* x measure of association. This performance measure shows the correlation between anesthetic depth indicator value and observed anesthetic depth, taking into account both desired performance and the limitations of the data. Prediction probability has a value of 1 when the indicator predicts observed anesthetic depth perfectly, and a value of 0.5 when the indicator predicts no better than a 50:50 chance. Prediction probability avoids the shortcomings of other measures. For example, as a nonparametric measure, PKis independent of scale units and does not require knowledge of underlying distributions or efforts to linearize or to otherwise transform scales. Furthermore, PKcan be computed for any degree of coarseness or fineness of the scales for anesthetic depth indicator value and observed anesthetic depth; thus, PKfully uses the available data without imposing additional arbitrary constraints, such as the dichotomization of either scale. And finally, PKcan be used to perform both grouped‐ and paired‐data statistical comparisons of anesthetic depth indicator performance. Data for comparing depth indicators, however, must be gathered via the same response‐to‐stimulus test procedure and over the same distribution of anesthetic depths.ConclusionsPrediction probability PKis an appropriate measure for evaluating and comparing the performance of anesthetic depth indicators.

 

点击下载:  PDF (11589KB)



返 回