The Measurement Of Very Low Level Bromate Ion
作者:
Gilbert Gordon,
Bernard Bubnis,
期刊:
Ozone: Science & Engineering
(Taylor Available online 1995)
卷期:
Volume 17,
issue 5
页码: 551-559
ISSN:0191-9512
年代: 1995
DOI:10.1080/01919512.1995.10555766
出版商: Taylor & Francis Group
关键词: Ozone;Bromate Ion Analysis;Chlorpromazine;Post Column Studies
数据来源: Taylor
摘要:
The potential to form BrO3−as a byproduct during ozone treatment of raw water containing bromide ion is a major concern for utilities planning to use ozone. The proposed BrO3−Maximum Contaminant Level (MCL) of 10 μg/L in the USA has been established largely by using ion chromatography. A spectrophotometric method based on the oxidation of chlorpromazine in the presence of BrO3−has been developed. The method detection limit (MDL) in reagent water is 0.8 μg/L BrO3−The procedure has an operating range of 1 to 40 μg/L BrO3. The precision of the method is calculated to be better than 2.5% with an accuracy within ± 1 μg/L BrO3−. Details of the method are presented along with data gathered by ion chromatography using borate and carbonate eluants; chlorpromazine post column studies; and low level capillary electrophoresis studies.