首页   按字顺浏览 期刊浏览 卷期浏览 Multiplexed piezoelectric polymer tactile sensor
Multiplexed piezoelectric polymer tactile sensor

 

作者: Edward S. Kolesar,   Rocky R. Reston,   Douglas G. Ford,   Robert C. Fitch,  

 

期刊: Journal of Robotic Systems  (WILEY Available online 1992)
卷期: Volume 9, issue 1  

页码: 37-63

 

ISSN:0741-2223

 

年代: 1992

 

DOI:10.1002/rob.4620090104

 

出版商: Wiley Subscription Services, Inc., A Wiley Company

 

数据来源: WILEY

 

摘要:

AbstractAn electrically multiplexed robotic tactile sensor has been realized using a monolithic silicon‐integrated circuit coupled to a piezoelectric polyvinylidene fluoride (PVDF) film. The integrated circuit incorporates 25 sensor electrodes arranged in a symmetrical 5 × 5 matrix. Each electrode occupies a 600 × 600 m̈m square area, and they are separated from each other by 600 m̈m. A 25‐m̈m thick PVDF film was experimentally determined to be compatible with the fabrication process, and also yielded very favorable tactile sensing performance characteristics. The response of the tactile sensor is essentially linear for loads spanning 0.8 to 60 g force (gmf). The response bandwidth is 33 Hz, the hysteresis level is very small, and crosstalk is not a significant problem. A novel precharge bias scheme has been implemented to stabilize the pre‐ and postload sensor response. A rudimentary tactile object image measurement process was evaluated to recognize the shapes of circular, rectangular, toroidal, and hexag

 

点击下载:  PDF (1748KB)