Method for evaluation of the acoustical impedance of a black box, with or without mean flow, measuring pressures at fixed positions
作者:
M. L. Kathuriya,
M. L. Munjal,
期刊:
The Journal of the Acoustical Society of America
(AIP Available online 1977)
卷期:
Volume 62,
issue 3
页码: 755-759
ISSN:0001-4966
年代: 1977
DOI:10.1121/1.381547
出版商: Acoustical Society of America
数据来源: AIP
摘要:
The transmission‐line or the impedance‐tube method for the measurement of the acoustic impedance of any termination involves a search for various minima and maxima of pressure. For this purpose, arrangement has to be made for the microphone to travel along the length of the impedance tube, and this complicates the design of the tube considerably. The present paper discusses a method which consists in evaluating the tube attenuation factor at any convenient frequency by making use of measured SPL’s at two (or more) fixed locations with a rigid termination, calculating the tube attenuation factor and wave number at the required frequency of interest with or without mean flow (as applicable), and finally evaluating the impedance of the given termination by measuring and using SPL’s at three (or more) fixed locations. Thus, the required impedance tube is considerably smaller in length, simpler in design, easier to manufacture, cheaper in cost and more convenient to use. The design of the tube is also discussed. Incidentally, it is also possible to evaluate the impedance at any low frequency without having to use a larger impedance tube.