首页   按字顺浏览 期刊浏览 卷期浏览 Effect of Dialysate Temperature on Peritoneal Clearances
Effect of Dialysate Temperature on Peritoneal Clearances

 

作者: Suchati Indraprasit,   Ampaporn Namwongprom,   Cha-onsin Sooksriwongse,   Prapai Suthavi Buri,  

 

期刊: Nephron  (Karger Available online 1983)
卷期: Volume 34, issue 1  

页码: 45-47

 

ISSN:1660-8151

 

年代: 1983

 

DOI:10.1159/000182977

 

出版商: S. Karger AG

 

关键词: Dialysate temperature;Peritoneal clearance;Dialysis technic

 

数据来源: Karger

 

摘要:

Peritoneal dialysis was performed in 18 uremic patients using both room temperature (27–31°C) and pre-warmed (37°C) dialysate. There were no significant differences between the two periods of the following parameters: urea clearance, creatinine clearance, inulin clearance, ratio of inulin to urea clearance, ratio of inulin to creatinine clearance, drainage volume, dialysate flow rate, ultrafiltration rate and total protein loss. Since the peritoneal dialysis efficiency was not improved by warming dialysate in this range of temperature, the warming procedure is not necessary in the countries where the average room temperature is 29°C (27–31°C). The exclusion of this procedure will decrease the work load and lessen the chance of dialysate contam

 

点击下载:  PDF (581KB)