Effect of Dialysate Temperature on Peritoneal Clearances
作者:
Suchati Indraprasit,
Ampaporn Namwongprom,
Cha-onsin Sooksriwongse,
Prapai Suthavi Buri,
期刊:
Nephron
(Karger Available online 1983)
卷期:
Volume 34,
issue 1
页码: 45-47
ISSN:1660-8151
年代: 1983
DOI:10.1159/000182977
出版商: S. Karger AG
关键词: Dialysate temperature;Peritoneal clearance;Dialysis technic
数据来源: Karger
摘要:
Peritoneal dialysis was performed in 18 uremic patients using both room temperature (27–31°C) and pre-warmed (37°C) dialysate. There were no significant differences between the two periods of the following parameters: urea clearance, creatinine clearance, inulin clearance, ratio of inulin to urea clearance, ratio of inulin to creatinine clearance, drainage volume, dialysate flow rate, ultrafiltration rate and total protein loss. Since the peritoneal dialysis efficiency was not improved by warming dialysate in this range of temperature, the warming procedure is not necessary in the countries where the average room temperature is 29°C (27–31°C). The exclusion of this procedure will decrease the work load and lessen the chance of dialysate contam