首页   按字顺浏览 期刊浏览 卷期浏览 Comparison of NbTi and Nb3Sn Material Tests with the Actual Performance of Coils
Comparison of NbTi and Nb3Sn Material Tests with the Actual Performance of Coils

 

作者: D. L. Coffey,   W. F. Gauster,   M. S. Lubell,  

 

期刊: Journal of Applied Physics  (AIP Available online 1971)
卷期: Volume 42, issue 1  

页码: 59-65

 

ISSN:0021-8979

 

年代: 1971

 

DOI:10.1063/1.1659653

 

出版商: AIP

 

数据来源: AIP

 

摘要:

A 100‐kG, 8.26‐cm‐bore, 40‐kJ Nb3Sn magnet and a 75‐kG, 10.2‐cm‐bore, 95‐kJ twisted filament NbTi magnet have been constructed and tested. A number of other magnets of smaller size using both the Nb3Sn and twisted filament NbTi conductors will also be described. Material evaluation tests leading to these magnet designs will be reported. They include short sample tests with controlled surface cooling conditions and cusp coil tests in which an external field is applied perpendicular to the cusp coil axis. Finally, two successful stabilization techniques for Nb3Sn ribbon will be presented with coil performance data before and after the stabilization has been employed.

 

点击下载:  PDF (421KB)