首页   按字顺浏览 期刊浏览 卷期浏览 Use of the Single-Plate Molteno Implant in Refractory Glaucoma
Use of the Single-Plate Molteno Implant in Refractory Glaucoma

 

作者: A. Mermoud,   J.F. Salmon,   C. Straker,   A.D.N. Murray,  

 

期刊: Ophthalmologica  (Karger Available online 1992)
卷期: Volume 205, issue 3  

页码: 113-120

 

ISSN:0030-3755

 

年代: 1992

 

DOI:10.1159/000310324

 

出版商: S. Karger AG

 

关键词: Refractory glaucoma;Traumatic glaucoma;Secondary glaucoma;Aphakic glaucoma;Molteno implant

 

数据来源: Karger

 

摘要:

During a 5-year period, 60 patients with uncontrolled glaucoma in one eye, who were considered to have a poor surgical prognosis with conventional drainage surgery, were treated with a single-plate Molteno implant. The surgery was performed in one operation and the tube tied with an absorbable suture in all cases. The overall follow-up was 20.3 ± 11 months (range 3–60). A successful outcome (defined as an intra-ocular pressure ≤21 mm Hg with or without treatment) was achieved in 56% of the 16 eyes with either aphakic or pseudophakic glaucoma, in 71% of the 14 eyes with uncontrolled glaucoma despite a previous filtering procedure, in 46% of the 13 eyes with traumatic glaucoma and in 64% of the 17 eyes with traumatic glaucoma and lens involvement. The visual acuity remained the same or better in 70% (42/60). Early complications of the surgery were transient and easily treated. Late complications included tube exposure in 3 (5%), tube retraction in 2 (3.3%), bleb encapsulation in 5 (8.3%) and corneal decompensation in 1 (1.65%). This study suggests that the single-plate Molteno implant is a useful drainage device with satisfactory results when used for the treatment of refractory secondary glaucoma.

 

点击下载:  PDF (2358KB)