首页   按字顺浏览 期刊浏览 卷期浏览 Measurement of Nuclear Isomeric Half‐Lives in the Range from One Microsecond to ...
Measurement of Nuclear Isomeric Half‐Lives in the Range from One Microsecond to Ten Milliseconds

 

作者: I. E. Lindstrom,   Bernd Crasemann,  

 

期刊: Review of Scientific Instruments  (AIP Available online 1959)
卷期: Volume 30, issue 5  

页码: 363-366

 

ISSN:0034-6748

 

年代: 1959

 

DOI:10.1063/1.1716624

 

出版商: AIP

 

数据来源: AIP

 

摘要:

Relatively simple and accurate delayed‐coincidence apparatus for the measurement of isomeric half‐lives in the millisecond range is described. Practical aspects of the statistics of delayed‐coincidence counting are discussed. Half‐life measurements of Ta181m(17.83±0.10 &mgr;sec) and Y88m(300.5±5.0 &mgr;sec) are described.

 

点击下载:  PDF (241KB)