首页   按字顺浏览 期刊浏览 卷期浏览 Detection of trace amounts of toxic metals in environmental samples by laser-excited at...
Detection of trace amounts of toxic metals in environmental samples by laser-excited atomic fluorescence spectrometry. Invited lecture

 

作者: Mikhail A. Bolshov,  

 

期刊: Journal of Analytical Atomic Spectrometry  (RSC Available online 1992)
卷期: Volume 7, issue 2  

页码: 99-104

 

ISSN:0267-9477

 

年代: 1992

 

DOI:10.1039/JA9920700099

 

出版商: RSC

 

数据来源: RSC

 

摘要:

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY MARCH 1992 VOL. 7 99 Detection of Trace Amounts of Toxic Metals in Environmental Samples by Laser-excited Atomic Fluorescence Spectrometry* Invited Lecture Mikhail A. Bolshov,t Vsevolod G. Koloshnikov and Sergei N. Rudnev Institute of Spectroscopy USSR Academy of Sciences 142092 Troitzk Moscow Region Russia Claude F. Boutron and Ursula Gorlach Laboratoire de Glaciologie et Geophysique de I'Environndment du CNRS Domaine Universitaire 2 rue Moliere B.P. 96 38402 St. Martin d'Heres Cedex France Clair C. Patterson Division of Geological and Planetary Sciences 1 70-25 California Institute of Technology Pasadena CA 91125 USA Results for the direct determination of trace amounts of Pb and Cd in Antarctic and Greenland ancient ice and recent snow by laser-excited atomic fluorescence spectrometry (LEAFS) are presented. The whole procedure starting from field sampling mechanical decontamination of the samples in an ultra-clean laboratory and final analysis of the decontaminated samples is described.The measured concentrations varied in the ranges 0.1 -3 pg ml-l for Cd and 0.3-30 pg ml-l for Pb. The results for direct analysis by LEAFS agree favourably with those obtained by isotope dilution mass spectrometry and electrothermal atomic absorption spectrometry which require time-consuming pre-treatment and pre-concentration stages. Keywords Trace amounts of toxic metals; laser-excited atomic fluorescence spectrometry; Antarctic and Greenland ice and snow; direct analysis Over the last two decades there has been a continuing increasing interest in the investigation of the concentrations of toxic heavy metals (such as Pb Cd Hg and Bi) in the environment.It is well known that human industrial activities have strongly modified the natural occurrence of these metals. Correct estimation of the difference between the natural (pre-industrial) and modem heavy metal con- tent of the environment is of great scientific interest. The best approach to the problem is the investigation of toxic metal occurrences in the well preserved dated snow and ice layers deposited in the remote Antarctic and Greenland ice This is indeed a unique way to reconstruct the past natural tropospheric cycles of these metals and to assess their recent alteration by man in both hemisphere^.^^^ Despite the growing interest there are at present few reliable data for the Pb Cd and Zn contents in Antarctic and Greenland ice and snows because the minimum concentrations of these metals to be measured are ex- tremely low (down to 0.3 pg ml-' of Pb and less than 0.1 pg ml-I of Cd).Such low concentrations manifest a serious challenge for a complete analytical project starting from field sampling then transportation sample pre-treatment and the final analysis. The great difficulties of maintaining the highest levels of clean and uncontaminated conditions at every stage of the project were the reason for a large number of erroneous results being published at the very beginning of the exercise. Even with the cleanest field sampling procedures most samples especially deep ice cores are contaminated on the outside.Reliable and accurate results could only be ob- tained after developing efficient ultra-clean procedures to decontaminate the sample^.^*^*^ The decontaminated * Presented at the XXVII Colloquium Spectroscopicum Interna- 7 To whom correspondence should be addressed. tionale (CSI) Bergen Norway June 9- 14 199 l . samples must then be analysed using ultra-clean and ultra- sensitive techniques. Up until the last 2-3 years the analytical techniques which had been used for the final analysis were either isotope dilution mass spectrometry (IDMS)1-2*6 or electro- thermal atomic absorption spectrometry (ETAAS).3v7v8 Un- fortunately both techniques are not sufficiently sensitive for direct measurements of the decontaminated samples.For IDMS a complicated chemical pre-treatment and large sample volumes (30-500 ml) are required to extract a sufficient amount of analyte for the final analysis. For ETAAS a pre-concentration step and large sample volumes (30-100 ml) are also necessary. The ultra-sensitive technique of laser-excited atomic fluorescence spectrometry (LEAFS) with electrothermal atomization offered a very promising alternative for the direct determination of toxic metals at and below the pg ml" level. The first measurements of Pb9 and Cdlo in Antarctic and Greenland ice and snows demonstrated the great potential of LEAFS as the analytical technique eventually used in the programme for monitoring toxic metals in ancient ice and snows. Results of an international collaboration between scien- tists from France the USA and USSR in the direct determination of Pb and Cd in Antarctic and Greenland ancient ice and recent snows are presented.Experimental Samples and Reagents The samples analysed for the Pb and Cd contents were 14 sections of the 905 m Dome C deep Antarctic ice core 6 sections of the 2083 m Vostok deep ice core and 18 samples of fresh snow collected on a precipitation event basis at Dye 3 station South Greenland. The Dome C core was collected by thermal drilling at the French station Dome C in a dry100 JOURNAL OF ANAL.YTICAL ATOMIC SPECTROMETRY MARCH 1992 VOL. 7 hole without a wall retaining liquid. It covers the past 40 000 years BP. The core from the Soviet Antarctic station at Vostok was thermally drilled in a hole filled with a wall retaining liquid (kerosene).It covers the past 155000 years BP. All these core sections were transported frozen in double sealed polyethylene bags from the Antarctic to Patterson's clean laboratory at the California Institute of Technology (Caltech Division of Geological and Planetaw Sciences Pasadena CA USA). The sections were about 10 cm in diameter and 15-30 cm in length. They were decontami- nated inside the Caltech clean laboratory by mechanically chiselling successive veneers of ice (each 6- 10 mm thick) in progression from the outside to the interior of the core using ultra-clean stainless-steel chisels. The whole proce- dure was performed on a cooled double-walled nitrogen- flushed ultra-clean polyethylene tray. The procedure has been described in detail elsewhere.6 The remaining inner cores were 2-4 cm in diameter.The chiselled ice from a particular veneer (or inner core) was allowed to melt overnight at room temperature in an ultra-clean conventional polyethylene beaker. The melted samples were then acidified to be 0.1 % in HN03 using ultra- pure HN03 prepared at the National Institute of Standards and Technology (NIST) Gaithersburg MD USA. The acidified solutions were allowed to stand for 2 h then 50- 100 ml aliquots were transferred into 250 ml precondi- tioned polyethylene bottles packed inside acid cleaned polyethylene bags and immediately frozen. Specific sub- samples of these prepared samples were then analysed at Caltech by IDMS. The residual samples were then transpor- ted frozen to the Laboratoire de Glaciologie et Geophysi- que de 1'Environnement (LGGE) France.Inside the LGGE clean laboratory the residual samples were allowed to melt at room temperature and 5-10 ml sub- aliquots were transferred into 30 ml preconditioned poly- ethylene bottles and packed inside acid cleaned polyethyl- ene bags. These sub-aliquots were then transported frozen to the Institute of Spectroscopy (ISAN) USSR. All of the polyethylene beakers and bottles used for pre- treatment and storage of the ice samples and for the synthetic standards had been previously cleaned both at Caltech and at the LGGE clean laboratories. The cleaning procedures were similar to those reported in refs. 2 9 and 11 and described in detail elsewhere.12 Aqueous standard solutions used in the experiments were synthetic acidified (0.1 Oh NIST HN03) multi-elemental standards.These standards contained 1 9 elements accord- ing to typical elemental concentration ratios expected in the Antarctic ice. They were prepared in the LGGE clean laboratory from Baker or Fisher certified atomic absorption standards (1 mg ml-' solutions). The procedure for the preparation of the standards has been described elsewhere9 and differed in some details from the typical procedure of successive dilutions. The concentrations of the standards used in the LEAFS measurements varied in the 1-250 pg ml-I range for Pb and 0.1-25 pg ml-I range for Cd. Apparatus Ancient Antarctic ice and recent snows were analysed using the laser atomic fluorescence analytical spectrometer (LA- FAS-1) instrument designed and constructed at ISAN.A detailed description of the LAFAS-1 has been given elsewhere,13 hence only a brief description of the main units of the spectrometer will be given here. Radiation source Tunable dye lasers (DL) and the associated optical har- monics have been the most widely used sources for LEAFS so far. In the LAFAS-1 instrument the DL was pumped by Table 1 Typical parameters of the DL and SHG pulses (for a pulse energy of the pumping XeCl laser of 10 mJ) Parameter Pb Cd Dye laser Rhodamine N Coumarine 47 EnergyImJ 0.7 0.8 Durationhs 10 10 Power/kW 70 80 Second harmonic KDP KB5 Energyljd 25 2 Durationhs 8 8 PowerIkW 3 0.25 a XeCl excimer laser with a moderate pulse energy of 10 rnJ with a pulse duration of 10 ns and repetition frequency of up to 25 Hz.The oscillator-amplifier scheme of the transverse- pumped DL was used. The wavelength of the DL was tuned and stabilized by the computer-controlled original grating assembly and control unit. The time required for setting a wavelength was 40 ms. The range of angle rotation of the grating controlled by the electrodynamic drive was 2". This range is sufficient to cover the entire tuning range of a particular dye. Tunable ultraviolet radiation below 300 nm was obtained by second harmonic generation (SHG) of the DL radiation in non-linear crystals. Two types of crystals were used KDP (40 mm in length 15x30 mm2 cross-section) for the determination of Pb and KB5 ( 1 7 mm in length 5 x 8 mm2 cross-section) for the determination of Cd. The parameters of the DL and SHG radiation for the two analytes are listed in Table 1.Lead atoms were excited at the 283.3 nm line and direct- line fluorescence was recorded at 405.8 nm. As the structure of the electronic levels of the Cd atoms does not allow fluorescence to be recorded at any shifted line the reso- nance scheme of Cd excitation and recording at the strongest line at 228.8 nm was used. Atomizer In the LAFAS- 1 instrument electrothermal atomization of the sample was used. The samples could be atomized both in a controlled inert atmosphere or under vacuum. Up to 50 pl of the sample can be introduced into a graphite cup pressed between the graphite electrodes. In the experiments with Pb laboratory-made and pyrolytic graphite coated graphite cups were used whereas in the experiments with Cd Ringsdorff pyrolytic graphite coated graphite cups were used.The latter proved to be cleaner and produced more stable signals with lifetimes approximately twice as long as the former. The temporal profile of the analytical signals was more reproducible with the Ringsdorff cups. The maximum temperature of the cup was 2700 "C and the temperature was controlled and stabilized by monitoring the radiation of the cup. The optimum heating programmes for Pb and Cd are listed in Table 2. The laser beam profile over the cup was shaped by a system of diaphragms and lenses in front of the input window of the chamber. The scattering of the laser radiation was a serious problem for the resonance fluores- cence of Cd. To minimize this scattering the beam formation system was improved in comparison with that described in ref.13. The major changes were made in order to decrease the extent of the optical surfaces prior to the chamber and reduce the scattering of the laser beam at large angles. The improved optical scheme is shown in Fig. 1 and described in detail in ref. 14.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY MARCH 1992 VOL. 7 101 Table 2 Atomization programmes for Pb and Cd Temperature/ "C Step Pb Cd Dry 95 90 Ash 600 180 Atomize 1600 1000 Clean 2000 1200 Cool 20 20 Ramp rate/ "C s-' Hold time/ S Argon flow rate/ 1 min-' Pb Cd 40 30 80 80 700 500 700 500 - - Pb Cd 30 210 10 10 4 4 5 5 40 50 Pb Cd 3 6 3 3 3 3 0 0 0 0 Atomizer cell Fig. 1 Modified optical scheme of the LAFAS-1 spectrometer Ll-L3 lenses; PI and P2 prisms; D1 and D2 diaphragms; W 1 input window; and W2 output window Recording system Fluorescence photons were collected at an angle of 90" on the entrance slit of the monochromator (relative aperture 1:3.7 reciprocal linear dispersion of 6.3 nm rnm-l) by a telescopic system.Fluorescence was recorded by a photo- multiplier tube FEU- 100 and a charge sensitive analogue- to-digital converter (ADC). The ADC output numerical code was fed to the computer for further processing. Neutral light filters were used to attenuate the intensity of the fluorescence for high concentrations of analyte. Analytical methodology In order to reduce contamination of the standards and samples the LAFAS-1 instrument was located inside a specially designed room supplied with filtered air. In addition the atomizer recording system associated elec- tronics and a special table covered with polyethylene film for the standards and samples were placed inside a clean chamber.The ventilation system of the chamber provided high efficiency filtering of the air and a laminar vertical flow of clean air inside the chamber. Both the samples and standards were introduced into the cup manually with a 20 pl Eppendorf micropipette. Each new polypropylene tip of the micropipette was cleaned before the first use by dipping for 2-3 min into concen- trated laboratory-reagent grade HN03 followed by several consecutive rinsings with 1% HN03 (NIST doubly dis- tilled diluted in LGGE ultra-pure water). In the course of the experiments the tip was cleaned in three consecutive bottles of 1% HN03 before every sample insertion.Typi- cally one tip was used for one working day for all the standards and samples provided there was no accidental contamination. Results Calibration of the LAFAS-1 Instrument Detailed calibration of the LAFAS-1 instrument was per- formed using the synthetic acidified standards described above. The following sets of standards were used 1 2.5 5 10 25 50 100 and 250 pg ml-I of Pb and 0.1 0.25 0.5 1.0 2.5 5.0 10.0 and 25.0 pg ml-I of Cd. Each standard was measured 2-3 times. Full sets of the analytical signals measured (numerical values) have been published else- where .9* lo The regression lines were constructed for both analytes by the least-squares method in the form Log A,=log a+b log Ci where Ai is the analytical signal (ADC code arbitrary units) Ci is the analyte concentration in the ith standard and b is the slope of the regression line.The limit of detection (LOD) was obtained for both analytes by extrapolation of the regression line to three standard deviations of the background. The parameters of the regression lines and LODs for Pb and Cd are listed in Table 3. The concentra- tion of Pb in LGGE ultra-pure water was found from the regression line to be 0.28 pg ml-I which is in excellent agreement with the value of 0.27 pg ml-l previously determined by IDMS. The concentrations of Pb in the Caltech and Cd in the LGGE and Caltech ultra-pure waters were found to be below the LODs for the LAFAS-1 instrument. Outer-Inner Profiles of the Deep Ice Cores In spite of all the precautions taken during field sampling the outermost veneers of all the core sections were contami- nated to some extent during drilling and packaging.To obtain the true values of the toxic metals content of a particular ice section all veneers of the section should be analysed. If an 'outer-inner' profile exhibits a plateau for the analyte concentration from the second or third layer to the inner core it could be stated that the surface contamina- tion did not penetrate to the central part of the section. The plateau concentration then represents the metal concentra- tion in that section of the deep ice core. However if the profile exhibits a continuous decrease in the concentration from the outside to the central part the inner core concentration must be regarded as the upper limit. Profiles for the Cd content were measured using the LAFAS-1 instrument for 10 of the 14 sections of Dome C core and for all 6 sections of the Vostok core. Two types of Cd profiles Table 3 Parameters for the regression lines and LODs for Pb and Cd (log a values for C in pg ml-I) Analyte Loga 6 LOD/pgml-I Pb 2.36 0.92 0.18 Cd 3.71 1.03 0.07102 JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY MARCH 1992 VOL.7 1 10’ r - E cr $ 1 x 10‘ 0 .- c E c 2 10 8 2 2 ’ C 0 s (a) u 0 1 2 3 4 1 x lo-‘ i L 0 1 2 3 4 Radius of corelcm Fig. 2 External-internal profiles of Cd concentrations for the two deep ice core sections (a) Dome C 172 m (3846 years BP); and (b) Vostok 499 m (26200 years BP) with and without plateaus are shown in Fig.2. The same profiles have been measured for Pb previously by IDMS6 and some of the results were checked with the LAFAS- 1. Ancient Antarctic Ice Samples Initially contamination caused by the chiselling procedure and from the ultra-pure HN03 and the water the walls of the bottles and beakers the air inside the laboratory etc. were carefully determined in numerous blank measure- ments. To do this an artificial ice core made by freezing Caltech ultra-pure water was chiselled and sub-divided using the same procedure as described above. Thus pre- pared blank samples were analysed for the Pb content by IDMS at Caltech and for the Cd content using LAFAS-1 at ISAN. The blank values were found to be about 0.11 pg ml-I for Pb and about 0.06 pg m1-I for Cd.All the determined concentrations of the analytes in ice samples were corrected for these blank values. All of the measurements made using the LAFAS-1 instrument were made with sample volumes of 20 pl for Pb and 50 pl for Cd. The full sets of the experimental data for both analytes have been published else~here.~+’~ The confidence intervals (CIS) for the measured concentrations were calculated using eqn. 8 from ref. 15 or eqn. (3) from ref. 9. For most samples the CI values (at the 95% confidence level) ranged from about 30 up to 5Ooh of the measured concentration. Variations in the Pb and Cd concentrations with depth in the Dome C and Vostok ice cores are shown in Figs. 3 and 4 respectively. It should be noted that there is very good agreement between the IDMS and LEAFS data for Pb.For most sections the results coincided to within the limits of experimental error which strongly supports the accuracy obtainable with both analytical techniques. The LAFAS-1 data for Cd are the first accurately measured values with estimated CIS for all sections of the Dome C and the Vostok ice cores. Previously published16 Cd concentrations for the Dome C provided only upper limits for many sections because even after preconcentra- tion the Cd contents of these samples were below the LOD for ETAAS. The lowest concentration of Cd (0.10 pg ml-l) was obtained for the 500.5 m Dome C section (14 000 years BP). For a 50 pl sample volume this corresponds to only 5 fg of Cd in the sample. In Fig. 3 several data points (open circles) represent the Cd values that should be carefully checked at some future date.For these sections the ‘outer-inner’ profiles are not Age of sample/l O3 years BP 0 10 20 30 40 30 - E 0 20 0 .- c I 8 8 + n P 10 0 4 3 I - E 0 P 0 \ .- 2 E El c 0) C 0 0 1 0 Sample depth/m Fig. 3 Variations of the Pb and Cd concentrations in the Dome C deep ice core as a function of the age of the ice A IDMS Pb values; B LAFAS-1 Pb values; C LAFAS-1 Cd values (sections with a concentration plateau); and D LAFAS-1 Cd values (sections without a concentration plateau) monotonic as the Cd concentrations in inner cores are higher than in some of the outer layers. This could be due to possible contamination during sample pre-treatment and/ or sub-dividing of the samples. The result for the section at 602 m is particularly dubious as the Cd concentration in the inner core is 3.1 pg ml-1 but it is 0.6 pg ml-1 in the previous (sixth) layer.It should be pointed that the Pb concentration in this same 602 m section is fairly ‘normal’. Without this dubious point for 602 m the Dome C profile for Cd qualitatively matches the Pb profile. Matching of the profiles for the two analytes is even better for the Vostok ice core. Greenland Fresh Snow A comparative determination of Cd in Greenland fresh snow was carried out using the LEAFS and ETAAS techniques. Because of significant anthropogenic input the Cd concentrations are relatively high in the range 1-10 pg m1-I in recent Greenland snow. These Cd contents can be measured by ETAAS after preconcentrati~n.~~~~~ The :samples of fresh snow were collected on a precipitation event basis from January to August 1989 at Dye 3 South Greenland as part of the ‘Dye 3 Gas and Aerosol Sampling Program’ of the US National Science Foundation.Eighteen samples of snow were analysed by LEAFS and ETAAS. The result of direct analyses using the LAFAS-1 and the analysis of preconcentrated samples using a Perkin-Elmer 2380 :spectrometer (HGA-500 graphite furnace 50 pl for 3 x 50 pl injections) are listed in Table 4. It can be seen that LAFAS-1 and ETAAS data are again in excellent agree- ment,which strongly supports the accuracy obtainable with both techniques.JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY MARCH 1992 VOL. 7 103 Age of sarnp~e/l o3 years BP 0 40 80 120 160 1 1 1 B 40 7 30 - E 0 0. 0 \ .- c h 8 20 00 c c n P 10 0 500 lo00 1500 2000 Sample depth/m 4 3 - E n 0 -r 0 .C c 4- !! 00 2 C 0 0 1 0 Fig. 4 Variations of the Pb and Cd concentrations in the Vostock deep ice core as a function of the age of the ice A IDMS Pb values; B LAFAS-1 Pb values; and C LAFAS-1 Cd values Discussion The sensitivity of the LEAFS technique is excellent as it is several orders of magnitude better than IDMS and ETAAS for the determination of Pb and Cd.For all samples measured the results for both Pb and Cd using the LAFAS-1 instrument and by IDMS or ETAAS are in excellent agreement. It must however be emphasized again that the LAFAS-1 measurements required only 20 pl of sample for the Pb and 50 pl of sample for the Cd Table 4 Comparative determination of Cd in Greenland fresh snows by LEAFSo and ETAAS6 (with preconcentration) Cd concentration ( ? standard deviation n= 3)/pg ml-I date ( 1 989) LAFAS- 1 ETAAS Sampling January 7 February 23 April 10 April 15 April 19 April 21 April 25 April 29 June 5 June 10 June 15 June 25 June 26 July 2 July 16 July 18 August 5 August 6 1.6 f 0.9 2.1 2 1.2 0.88 2 0.50 3.02 1.7 1.1 k0.6 1.72 1.0 0.4 1 k 0.24 1.3 f 0.7 2.5f 1.4 7.3 f 4.2 2.3 k 1.3 8.0 f 5.1 1.520.9 0.94 k 0.53 3.5 f 2.0 0.31 20.18 0.47 k 0.27 2.92 1.6 1.4 f 0.4 4.0 f 0.6 1 .O f 0.3 4.2 A 0.6 1.5 k0.3 2.0 ? 0.4 0.2 5 0.2 1.7f0.4 2.9 f 0.5 8.95 1.0 2.4 k 0.4 14.5k 1.4 2.4 & 0.4 0.9 k 0.4 4.2 5 0.6 0.2 5 0.2 0.6 f 0.4 3.1 k 0.5 determinations.On the other hand for the IDMS measure- ments 50-200 ml of sample and a difficult and time- consuming chemical pre-treatment stage were required for analyses at the pg ml-l level.In addition one sample analysis can take at least half a day. For the ETAAS measurements 50 ml of sample and time-consuming preconcentration were necessary. In these first applications of the LEAFS technique to the direct determination of trace amounts of Pb and Cd in ancient ice and recent snow the main goal was to compare the results with those obtained by IDMS or ETAAS for as large a concentration range as possible and for samples taken from different sections' of deep ice cores and different geographic locations. There could have been a systematic difference as the speciation of the analytes may not have been the same during the different geologic epochs Holo- cene Last Glacial Maximum (LGM) Wisconcin and Last Interglacial. During this first stage of the project it was decided to analyse the maximum amounts of samples from different sections but most samples were measured only once.Only very unexpected and dubious results for a number of samples (such as the Cd content in the 602 m Dome C section) were repeated two or three times. The small number of measurements caused the relatively wide CIS obtained (30-50%). Obviously much narrower CIS could be obtained in the future with more extensive sets of measurements. The different sources of Pb in Antarctic ancient ice were carefully determined and discussed in previous ~ o r k . ~ J ~ It was shown that the main sources of atmospheric Pb are soil dust and volcano plumes. The contribution from the oceans is insignificant throughout the period studied.The time variations of the Pb concentration faithfully tracks varia- tions in the soil dust Pb concentration calculated from aluminium concentrations in ice thus proving that most of the natural Pb in the global atmosphere originated from soil dust during both the late Wisconsin (LGM) and the next to last ice age. The contribution to the Pb content from volcanoes calculated from sulphate concentrations in the ice was negligible during the late Wisconcin and next to last ice age but accounts for about half of the measured total Pb during the Holocene age. A detailed interpretation of changes in Cd concentration in the Antarctic is given ref. 20. These data for the Pb and Cd contents in deep ice cores confirm that prior to human industrial activities there were no excesses of the two toxic metals above that contributed by soil dust and volcanoes.Now more than 99% of Pb in the troposphere of the Northern Hemisphere originates from human activities. Anthropogenic Cd emissions to the atmosphere (about 7600 tonnes per year in 1983*'~~~) are now surpassing natural Cd emissions from rocks and soils sea-salt spray volcanoes and biogenic sources (about 1300 tonnes per year).22 References 1 Murozumi M. Chow T. J. and Patterson C. C. Geochim. Cosmochim. Acta 1969 33 1247. 2 Ng A. and Patterson C. C. Geochim. Cosmochim. Acta 1981,45 2109. 3 Wolf E. W. and Peel D. A. Nature (London) 1985,313,535. 4 Peel D. A. in The Environmental Record in Glaciers and Ice Sheets ed.Oeschger H. and Langway C. C. Jr. Dahlem Konferenzen Wiley New York 1989 p. 207. 5 Boutron C. F. and Gorlach U. in Metal Speciation in [he Environment ed. Broekaert J. A. C. Gucer S. and Adams F. Springer Verlag Berlin 1990 p. 137. 6 Boutron C. F. and Patterson C. C. Nafure(London) 1986 323 222. 7 Wolf E. W. and Peel D. A. Ann. Glaciol. 1988 10 193.104 JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY MARCH 1992 VOL. 7 8 Wolf E. W. and Peel D. A. Ann. Glaciol. 1985 7 61. 9 Bolshov M. A. Boutron C. F. and Zybin A. V. Anal. Chern. 1989,61 1758. 10 Bolshov M. A. Boutron C. F. Ducroz F. M. Gorlach U. Kompanetz 0. N. and Rudnev S. N. Anal. Chim. Acta 199 1 251 169. I 1 Boutron C. F. and Patterson C. C. Geochim. Cosmochirn. Acta 1983 47 1355. 12 Boutron C. F. Fresenius J. Anal. Chem. 1990 337 482. 13 Apatin V. M. Arkhangelskii B. V. Bolshov M. A. Ermolov V. V. Koloshnikov V. G. Kompanetz 0. N. Kuznrtsov N. I. Mikhailov E. L. Shishkovskii V. S. and Boutron C. F. Spectrochim. Ada Part B 1989 44 253. 14 Bolshov M. A. Hutsch B. and Rudnev S. N. J. Anal. At. Spectrom. 1992 7 1. 15 Bolshov M. A. Dashin S. A. Zybin A. V. Koloshnikov V. G. Mayorov I. A. and Smirenkina I. I. Zh. Anal. Khim. 1986 41 1862. 16 Batifol F. Boutron C. F. and de’Agelis M. Nature (London) 1989,337 544. 17 Gorlach U. and Boutron C. F. in Heavy Metals in the Environment ed. Vemet J. P. CEP Consultants Edinburgh 1989 p. 24. 18 Ducroz F. Gorlach U. Jaffrezo J. L. and Boutron C. F. unpublished data. 19 Boutron C. F. Patterson C. C. Petrov V. N. and Barkov N. I. Atmos. Environ. 1987 21 1197. :20 Nriagu J. O. and Pacyna J. M. Nature (London) 1988,333 134. :2 1 Nriagu J. O. Nature (London) 1989 338 47. Paper 1 /03030B Received June 17 I991 Accepted July 9 1991

 

点击下载:  PDF (727KB)



返 回