首页   按字顺浏览 期刊浏览 卷期浏览 Effects of Clonidine on Narcotic Requirements and Hemodynamic Response during Induction...
Effects of Clonidine on Narcotic Requirements and Hemodynamic Response during Induction of Fentanyl Anesthesia and Endotracheal Intubation

 

作者: M. Ghignone,   L Quintin,   P. Duke,   C. Kehler,   O. Calvillo,  

 

期刊: Anesthesiology  (OVID Available online 1986)
卷期: Volume 64, issue 1  

页码: 36-42

 

ISSN:0003-3022

 

年代: 1986

 

出版商: OVID

 

关键词: Anesthetics intravenous: fentanyl;Pharmacology: clonidine;Premedication: clonidine;Sympathetic nervous system: alpha-adrenergic agonist, clonidine

 

数据来源: OVID

 

摘要:

The effects of clonidine, a centrally acting α2-adrenergic receptor agonist, on depth of fentanyl anesthesia and on cardiovascular response to laryngoscopy and intubation were studied. Twenty-four patients undergoing aortocoronary bypass surgery (ACBS) with a history of arterial hypertension, coronary artery disease (NYHA class 3–4), and well-preserved left ventricular function were assigned randomly to either Group 1 (n = 12), who received standard pre-medication, or Group 2 (n = 12), who received clonidine 5 μ;g·kg-1po in addition to standard premedication 90 min before estimated induction time. Depth of anesthesia was assessed by on-line aperiodic computerized analysis of the electroencephalogram (Lifescan EEG Monitor®). Fentanyl was administered in 250-μ;g increments to shift the EEG to the 0.5–3-Hz frequency range (delta activity) in all subjects. In both groups, the anesthetic regimen effectively prevented hyperdynamic cardiovascular responses to laryngoscopy and intubation. No significant differences in measured or derived hemodynamic variables were observed between the two groups during the awake control period, except for stroke volume index (SVI), which was significantly greater in Group 1,44 ± 9 ml · beat-1· M-2compared with Group 2, 35 ± 3.3 ml · beat-1· m-2(P< 0.05). By contrast, fentanyl requirements in Group 2 were significantly reduced by 45% when compared with Group 1, i.e., from 110 ± 23 to 61 ± 19 μ;g· kg-1(P< 0.001). The authors conclude that at a similar anesthetic depth, as assessed by the EEG shift into the lower frequency range (0.5–3 Hz), a markedly reduced fentanyl dose effectively prevented the hyperdynamic cardiovascular response to laryngoscopy and intubation in the group of patients premedicated with clonidine. This is likely explained by the known synergistic inhibitory action of opiates and α2-adrenoceptor agonists on central sympathetic outflow.

 

点击下载:  PDF (582KB)



返 回