首页   按字顺浏览 期刊浏览 卷期浏览 Measurement of the velocity of ultrasound in the human femurin vivo
Measurement of the velocity of ultrasound in the human femurin vivo

 

作者: Michael P. André,   J. Duncan Craven,   Moses A. Greenfield,   Richard Stern,  

 

期刊: Medical Physics  (WILEY Available online 1998)
卷期: Volume 7, issue 4  

页码: 324-330

 

ISSN:0094-2405

 

年代: 1998

 

DOI:10.1118/1.594713

 

出版商: American Association of Physicists in Medicine

 

数据来源: WILEY

 

摘要:

A pulse‐echo technique for measuring the velocity of ultrasound in the cortex of the femurin vivois presented. The average result for 27 asymptomatic volunteers is 3250±190 m/s. The results show no significant differences between proximal and distal femoral sites, right and left femora, males and females. There is also no significant difference between the velocity of sound in the femur and in the radius in normal volunteers. The reproducibility of the time of flight measurement for three volunteers is found to be about 2%, and the total uncertainty of the femoral velocity of ultrasound measurement is determined to be 4% for proximal sites and 7% for distal sites. As the femur is a load‐bearing bone, the site of frequent fracture both in the elderly and in the osteoporotic, the measurement of the velocity of sound at this new site may of great value in investigating these conditions and may ultimately be helpful in assessing ’'quality” of the femoral cortex in those patients undergoing total hip or knee replacement.

 

点击下载:  PDF (733KB)



返 回