首页   按字顺浏览 期刊浏览 卷期浏览 Estimation of pulmonary artery occlusion pressure by an artificial neural network
Estimation of pulmonary artery occlusion pressure by an artificial neural network

 

作者: Bennett deBoisblanc,   Andrew Pellett,   Royce Johnson,   Michael Champagne,   Espisito McClarty,   Gundeep Dhillon,   Michael Levitzky,  

 

期刊: Critical Care Medicine  (OVID Available online 2003)
卷期: Volume 31, issue 1  

页码: 261-266

 

ISSN:0090-3493

 

年代: 2003

 

出版商: OVID

 

关键词: artificial intelligence;pulmonary artery occlusion pressure;hemodynamic monitoring

 

数据来源: OVID

 

摘要:

ObjectiveWe hypothesized that an artificial neural network, interconnected computer elements capable of adaptation and learning, could accurately estimate pulmonary artery occlusion pressure from the pulsatile pulmonary artery waveform.SettingUniversity medical center.SubjectsNineteen closed-chest dogs.InterventionsPulmonary artery waveforms were digitally sampled before conventional measurements of pulmonary artery occlusion pressure under control conditions, during infusions of serotonin or histamine, or during volume loading. Individual beats were parsed or separated out. Pulmonary artery pressure, its first time derivative, and the beat duration were used as neural inputs. The neural network was trained by using 80% of all samples and tested on the remaining 20%. For comparison, the regression between pulmonary artery diastolic pressure and pulmonary artery occlusion pressure was developed and tested using the same data sets. As a final test of generalizability, the neural network was trained on data obtained from 18 dogs and tested on data from the remaining dog in a round-robin fashion.Measurements and Main ResultsThe correlation coefficient between the pulmonary artery diastolic pressure estimate of pulmonary artery occlusion pressure and measured pulmonary artery occlusion pressure was .75, whereas that for the neural network estimate of pulmonary artery occlusion pressure was .97 (p< .01 for difference between pulmonary artery diastolic pressure and pulmonary artery occlusion pressure estimates). The pulmonary artery diastolic pressure estimate of pulmonary artery occlusion pressure showed a bias of 0.097 mm Hg (limits of agreement −7.57 to 7.767 mm Hg), whereas the neural network estimate of pulmonary artery occlusion pressure showed a bias of −0.002 mm Hg (−2.592 to 2.588 mm Hg). There was no significant change in the bias of the neural network estimate over the range of values tested. In contrast, the bias for the pulmonary artery diastolic pressure estimate significantly increased with the increasing magnitude of the pulmonary artery occlusion pressure. During round-robin testing, the neural network estimate of pulmonary artery occlusion pressure showed suboptimal performance (correlation coefficient between estimated and measured pulmonary artery occlusion pressure .59).ConclusionsA neural network can accurately estimate pulmonary artery occlusion pressure over a wide range of pulmonary artery occlusion pressure under conditions that alter pulmonary hemodynamics. We speculate that artificial neural networks could provide accurate, real-time estimates of pulmonary artery occlusion pressure in critically ill patients.

 

点击下载:  PDF (283KB)



返 回