首页   按字顺浏览 期刊浏览 卷期浏览 In vivoinflammatory response to polymethylmethacrylate particulate debris: Effect of si...
In vivoinflammatory response to polymethylmethacrylate particulate debris: Effect of size, morphology, and surface area

 

作者: Howard Gelb,   H. Ralph Schumacher,   John Cuckler,   Daniel G. Baker,  

 

期刊: Journal of Orthopaedic Research  (WILEY Available online 1994)
卷期: Volume 12, issue 1  

页码: 83-92

 

ISSN:0736-0266

 

年代: 1994

 

DOI:10.1002/jor.1100120111

 

出版商: Wiley Subscription Services, Inc., A Wiley Company

 

数据来源: WILEY

 

摘要:

AbstractParticulate debris, including that from polymethylmethacrylate (PMMA) cement, is observed commonly in the membrane surrounding loose joint prostheses. Such debris is assumed to cause an inflammatory response and contributes to osteolysis and failure of the implant. A subcutaneous rat air‐pouch model was used to assess quantitatively thein vivoeffects of the size, morphology, and surface area of PMMA particles on the acute inflammatory response. PMMA particles were divided into three groups. In Group A, mechanical grinding of cured bone cement produced irregularly shaped particles; Group B included spherical particles of PMMA powder (Simplex P); and Group C consisted of commercially prepared spherical latex particles. All three groups had two size distributions:<20 μm and 50–350 μm. For a given mass or dose, the small, irregularly shaped mechanically produced particles in Group A elicited a significantly greater inflammatory reaction than the large particles in Group A, as expressed by the release of tumor necrosis factor (TNF), neutral metalloprotease (NMP), and prostaglandin E2(PGE2) and the white blood cell (WBC) count within a 24‐hour period. Similar findings were seen in Group B. Particles in Group C were used to compare the effect of absolute numbers of large and small particles and surface area. Large (10–126 μm) spherical PMMA particles at a dose of 1.7 × 106particles/ml caused a significantly higher inflammatory response, as measured by WBC count and production of NMP and PGE2, than small (1–10 μm) spheres at a dose of 4 × 106particles/ml. However, the production of TNF in the rats was significantly increased with small particles (p<0.05) at a concentration 4‐fold less than that with the large particles (4 × 105compared with 1.7 × 106particles/ml). This finding may reflect a different cellular mechanism for the TNF component of the inflammatory response than is measured by WBC counts or by levels of PGE2and NMP. As the calculated surface area of the PMMA particles increased, a threshold level was reached, at which point the inflammatory response increased dramatically. The size of particles has a role in the prolongation and intensity of the release of specific cytokines. The total surface area of the particles appeared to be an important factor in determining the inflammatory response, as measured by WBC count,

 

点击下载:  PDF (845KB)



返 回