An interferometric device to measure the mechanical transfer function of the VIRGO mirrors suspensions
作者:
E. Calloni,
L. Di Fiore,
A. Grado,
L. Milano,
期刊:
Review of Scientific Instruments
(AIP Available online 1998)
卷期:
Volume 69,
issue 4
页码: 1882-1885
ISSN:0034-6748
年代: 1998
DOI:10.1063/1.1148858
出版商: AIP
数据来源: AIP
摘要:
The design of servoloops for automating alignment and locking of long baseline gravitational wave detectors requires an accurate knowledge of the mechanical transfer function (TF) of the mirror suspensions. We present a suspended interferometric device devoted to the measurement of the TF of the multipendular seismic isolators of the VIRGO antenna. ©1998 American Institute of Physics.
点击下载:
PDF
(87KB)