Ion Chromatographie Determination of Anionic Impurities in the Secondary Water System of Nuclear Power Stations
作者:
F. Füchtner,
期刊:
Isotopenpraxis Isotopes in Environmental and Health Studies
(Taylor Available online 1989)
卷期:
Volume 25,
issue 9
页码: 415-418
ISSN:0021-1915
年代: 1989
DOI:10.1080/10256018908624168
出版商: Taylor & Francis Group
关键词: anions;chlorides;ion exchange chromatography;microanalysis;quantitative chemical analysis;reactor cooling systems;secondary coolant cireuits;sensitivity;sulates;trace amounts
数据来源: Taylor
摘要:
The nonsuppressed anion chromatography with indirect UV-detection is demonstrated as a suitable method for the trace-analysis in the secondary water system of nuclear power stations. Coated silica-based reversed phase material was used as ion exchanger. This material has a high chromatographic efficiency and selectivity. The used hardware allows the determination of chloride and sulfate with a detection limit of 0.8 ppb and a relative standard deviation of 20%.
点击下载:
PDF (272KB)
返 回