Flow - Injection Spectrophotometric Determination of Trace Amounts of Tellurium by Catalytic Reduction of Toluidine Blue
作者:
M.F. Mousavi,
M.R. Almasian,
期刊:
Analytical Letters
(Taylor Available online 1996)
卷期:
Volume 29,
issue 10
页码: 1851-1860
ISSN:0003-2719
年代: 1996
DOI:10.1080/00032719608001528
出版商: Taylor & Francis Group
关键词: Tellurium Determination;FIA;Toluidine Blue;Spectrophotometry
数据来源: Taylor
摘要:
Tellurium was determined spectrophotometrically at 635 nm and pH 5.3 based on its catalytic reduction of Toluidine Blue in the presence of Te(IV) by using a flow -injection system. Under the optimized experimental conditions, the detection limit is 60 ng/ml of tellurium ion and the linear range is 80–3800 ng/ml (110 μl, injection). The relative standard deviation of 10 replicate measurements is 1.5% for a 1.5 μg/ml of tellurium. The sampling rate is 25 h-1.