The application of electricity in mine pumping
作者:
G.B.Alvey,
N.Tetlow,
期刊:
Journal of the Institution of Electrical Engineers - Part II: Power Engineering
(IET Available online 1943)
卷期:
Volume 90,
issue 15
页码: 138-154
年代: 1943
DOI:10.1049/ji-2.1943.0025
出版商: IEE
数据来源: IET
摘要:
Electrically-driven mine-drainage pumps may be of the centrifugal or of the positive displacement reciprocating type. Since the characteristics of the driven pump have a considerable bearing on the choice of the most suitable driving motor, the first portion of the paper deals with operating and design characteristics of the two types of pump. The remainder of the paper shows how, by a study of these operating characteristics, the most suitable type of driving motor may be chosen.
点击下载:
PDF
(2259KB)
返 回