A Sensitive Differential Manometer
作者:
J. M. Los,
J. A. Morrison,
期刊:
Review of Scientific Instruments
(AIP Available online 1951)
卷期:
Volume 22,
issue 11
页码: 805-809
ISSN:0034-6748
年代: 1951
DOI:10.1063/1.1745767
出版商: AIP
数据来源: AIP
摘要:
A sensitive differential mercury manometer is described. Mercury surfaces in two arms of the manometer form plates of condensers connected to two nearly identical oscillator circuits. A change in pressure produces a change in the beat frequency of the oscillators which is measured by comparison on an oscilloscope with the output of an audiosignal generator. For 0<&Dgr;p<0.02 cm an accuracy of 0.1 to 0.2 micron of mercury is obtained. For &Dgr;pbetween 0.02 cm and the maximum measurable with the manometer (approximately 0.25 cm) the accuracy appears to be 0.1 percent or better.