首页   按字顺浏览 期刊浏览 卷期浏览 Unmeasured anions identified by the Fencl-Stewart method predict mortality better than ...
Unmeasured anions identified by the Fencl-Stewart method predict mortality better than base excess, anion gap, and lactate in patients in the pediatric intensive care unit

 

作者: Napa,   Balasubramanyan Peter L.,   Havens George M.,  

 

期刊: Critical Care Medicine  (OVID Available online 1999)
卷期: Volume 27, issue 8  

页码: 1577-1581

 

ISSN:0090-3493

 

年代: 1999

 

出版商: OVID

 

数据来源: OVID

 

摘要:

ObjectivesThis study was undertaken to compare three methods for the identification of unmeasured anions in pediatric patients with critical illness. We compared the base excess (BE) and anion gap (AG) methods with the less commonly used Fencl-Stewart strong ion method of calculating BE caused by unmeasured anions (BEua). We measured the relationship of unmeasured anions identified by the three methods to serum lactate concentrations and to mortality.DesignRetrospective cohort study.SettingTertiary care pediatric intensive care unit in an academic pediatric hospital.PatientsThe study population included 255 patients in the pediatric intensive care unit who had simultaneous measurements of arterial blood gases, electrolytes, and albumin during the period of July 1995 to December 1996. Sixty-six of the 255 patients had a simultaneous measurement of serum lactate.Measurements and Main Resultsor=to45 mg/dL was defined as being abnormally elevated for this study. The presence of unmeasured anions identified by significantly abnormal BEua was poorly identified by BE or AG. Of the 255 patients included in the study, 67 (26%) had a different interpretation of acid base balance when the Fencl method was used compared with when BE and AG were used. Plasma lactate concentration correlated better with BEua (r2= .55; p = .0001) than with AG (r2= .41; p = .0005) or BE (r2or=to45 mg/dL (relative risk of death = 2.35; p = .04). In logistic regression analysis, mortality was more strongly associated with BEua (area under the receiver operating characteristic curve = 0.79; p = .0002) than lactate (receiver operating characteristic curve area = 0.63; p = .05), BE (receiver operating characteristic curve area = 0.53; p = .32), or AG (receiver operating characteristic curve area = 0.64; p = .08) in this patient sample.ConclusionsCritically ill patients with normal BE and normal AG frequently have elevated unmeasured anions detectable by BEua. The Fencl-Stewart method is better than BE and similar to AG in identifying patients with high lactate levels. Elevated unmeasured anions identified by the Fencl-Stewart method were more strongly associated with mortality than with BE, AG, or lactate in this patient sample. (Crit Care Med 1999; 27:1577-1581)

 



返 回