1. |
Indoor air quality control by outdoor airflow variation in HVAC systems |
|
International Journal of Ambient Energy,
Volume 20,
Issue 3,
1999,
Page 115-124
F. Minichiello,
Preview
|
PDF (774KB)
|
|
摘要:
Indoor air quality control can be obtained by supplying outdoor airflow rates varying in dependence on measured or presumed contaminant concentrations. So outdoor airflow rates actually supplied to the ambient may be reduced with respect to design maximum values, with consequent consumption decrease. In the present paper some outdoor airflow rate control systems in HVAC plants are analysed.
ISSN:0143-0750
DOI:10.1080/01430750.1999.9675329
出版商:Taylor & Francis Group
年代:1999
数据来源: Taylor
|
2. |
Effect of thermal storage on the performance of a deep bed drying system |
|
International Journal of Ambient Energy,
Volume 20,
Issue 3,
1999,
Page 125-136
R.K. Goyal,
G.N. Tiwari,
Preview
|
PDF (629KB)
|
|
摘要:
The effect of thermal energy storage on deep bed grain drying is studied. The rate of evaporation of moisture and humidity of drying air are analysed with time of the day for different depths of bed, heat capacity of storage material and flow rate. The effect of thermal storage is also studied on the fluid temperature, grain temperature and on the overall performance of the system. A parametric study has been done for a typical day of the month of June for climatic conditions in Delhi. It has been observed that the bed moisture content decreases with time of day unlike the humidity of the drying air and grain temperature also decreases with heat capacity.
ISSN:0143-0750
DOI:10.1080/01430750.1999.9675330
出版商:Taylor & Francis Group
年代:1999
数据来源: Taylor
|
3. |
An optimal energy forecasting model for the economy environment match |
|
International Journal of Ambient Energy,
Volume 20,
Issue 3,
1999,
Page 137-148
L. Suganthi,
A.A. Samuel,
Preview
|
PDF (858KB)
|
|
摘要:
Econometric demand models which are used in developed countries consider only price and national income. The modified model developed earlier by the authors links energy consumption with the economy, technology and the environment. The modified model is validated by comparing with an econometric and time series regression model based on least squared error, square of correlation coefficient and Durbin Watson statistic (DW). It is found that in all cases the Modified Model gives the best results.
ISSN:0143-0750
DOI:10.1080/01430750.1999.9675331
出版商:Taylor & Francis Group
年代:1999
数据来源: Taylor
|
4. |
Numerical analysis of a tubular solar collector with cusp reflectors |
|
International Journal of Ambient Energy,
Volume 20,
Issue 3,
1999,
Page 149-158
R. Kumar,
S.C. Kaushik,
H.P. Garg,
N. Vatsa,
Preview
|
PDF (483KB)
|
|
摘要:
This paper discusses the transient performance of a tubular solar collector under different operating conditions. The different components, such as the cover, receiver envelope and receiver and fluid inside the cylindrical tube are considered as a separate node. The energy balance equations for each node are solved by using the finite difference technique. It is found that a tubular collector with a cusp reflector is better in performance than the evacuated tubular collector lone. The rise in the temperature and efficiency of the collector is a sensitive function of mass flow rate, length of the tube, gap between receiver and receiver envelope, optical and thermal properties of the cover, receiver envelope and receiver. For efficient use of solar energy, the length and gap between the receiver and receiver envelope are to be fixed at their optimum values (~ 1.0–1.5m and ~ 10 mm) and the flow rate kept as small as possible (~ 0.0001 kg/s).
ISSN:0143-0750
DOI:10.1080/01430750.1999.9675332
出版商:Taylor & Francis Group
年代:1999
数据来源: Taylor
|
5. |
Numerical and experimental studies of the condensation phenomenon on a loading platform |
|
International Journal of Ambient Energy,
Volume 20,
Issue 3,
1999,
Page 159-166
A. Hadjadj,
S. Maamir,
B. Zeghmati,
B.B. Gupta,
Preview
|
PDF (498KB)
|
|
摘要:
A numerical and experimental study of the condensation induced by the variation in the ambient temperature on a loading platform (of GEFCO, France) is presented. A theoretical model was developed in order to analyse the influence of different parameters, such as: the thermal characteristics of the work place, the air temperature, the relative humidity, the frequent opening of the doors in the building, the wind velocity and the effect of solar radiation, on the condensation. The experiments were performed using thermocouples and infrared thermography methods in order to validate the theoretical model. It was shown that by adopting a proper means for sufficient heat transfer from the ground to its surrounding, the condensation phenomenon can be suppressed or controlled.
ISSN:0143-0750
DOI:10.1080/01430750.1999.9675333
出版商:Taylor & Francis Group
年代:1999
数据来源: Taylor
|
6. |
Book Reviews |
|
International Journal of Ambient Energy,
Volume 20,
Issue 3,
1999,
Page 167-168
L.K. Dunbar,
J.C. McVeigh,
Preview
|
PDF (250KB)
|
|
ISSN:0143-0750
DOI:10.1080/01430750.1999.9675334
出版商:Taylor & Francis Group
年代:1999
数据来源: Taylor
|
7. |
Notes for Authors |
|
International Journal of Ambient Energy,
Volume 20,
Issue 3,
1999,
Page 169-169
Preview
|
PDF (84KB)
|
|
ISSN:0143-0750
DOI:10.1080/01430750.1999.9675335
出版商:Taylor & Francis Group
年代:1999
数据来源: Taylor
|
8. |
Editorial Board |
|
International Journal of Ambient Energy,
Volume 20,
Issue 3,
1999,
Page -
Preview
|
PDF (103KB)
|
|
ISSN:0143-0750
DOI:10.1080/01430750.1999.9675328
出版商:Taylor & Francis Group
年代:1999
数据来源: Taylor
|
|