1. |
Contrast Sensitivity Determined with the Spatial Bandwidth Equalization TechniqueThreshold, Suprathreshold, and Spatiotemporal Measurements |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 221-231
ROGER WILEY,
THOMAS HARDING,
MICHAEL GRIBLER,
ALBERT KIRBY,
Preview
|
PDF (709KB)
|
|
摘要:
Contrast sensitivity functions were obtained from normal subjects using a spatial bandwidth equalization (SBE) technique and the more conventional display method. Static sensitivity measurements obtained with the two methods were in good agreement. However, when the patterns were counterphase flickered, sensitivity to the lower spatial frequencies was enhanced using the conventional method while sensitivity measured with the SBE technique was slightly depressed. The SBE method also was used to investigate suprathreshold contrast perception with static and flickering gratings. In general, the perception of contrast was independent of spatial frequency content of the stimulus, especially with increasing contrast levels and flicker frequencies. These studies have shown that the SBE technique is an acceptable method to assess static contrast sensitivity and suprathreshold contrast perception.
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|
2. |
Effect ofIn VivoandIn VitroSurface Protein Deposits on the Oxygen Permeability of Polyhydroxyethylmethacrylate Gel Contact Lenses |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 232-238
STANLEY HUTH,
CHARLES LANNOM,
SUSAN LANNOM,
Preview
|
PDF (529KB)
|
|
摘要:
The effect of surface protein deposits on the oxygen permeability of polyhydroxyethylmethacrylate (polyHEMA) gel contact lenses was studied using: (1) previously worn lenses with protein deposits accumulatedin vivo, and (2) new lenses with protein depositedin vitro.The oxygen permeability (Dk) of the protein-depositedin vivolenses was determined before and after cleaning, and that of the new lenses before and afterin vitroprotein deposition. For both groups of lenses, the oxygen permeability did not change significantly after either cleaning (in vivolenses) or protein deposition (in vitrolenses). It is concluded that surface protein deposits on polyHEMA lenses do not alter the oxygen permeability of the lenses.
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|
3. |
Power and Radius Changes Induced in Soft Contact Lens Systems by Flexure |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 239-245
BARRY WEISSMAN,
KATHRYN GARDNER,
Preview
|
PDF (383KB)
|
|
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|
4. |
Development of Quantitative Tools for Filter‐Aided Dichromats |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 246-255
STUART RICHER,
ANTHONY ADAMS,
Preview
|
PDF (658KB)
|
|
摘要:
Historically, there has been little quantitative rationale for the prescription of colored filters for color deficients. A formal prediction of the effects of any filter on dichromat luminance and chromatic discrimination is presented; these predictions were generated by using colorimetric concepts and related derived formulas to create four interactive computer-graphic tools. In addition to predicting performance of presently available commercial filters, such tools can be used to describe, classify, and even design new filters.
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|
5. |
An Experimental Test of Filter‐Aided Dichromatic Color Discrimination |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 256-264
STUART RICHER,
ANTHONY ADAMS,
Preview
|
PDF (574KB)
|
|
摘要:
Using derived formulas for dichromat colorimetry and related computer graphic colorimetric tools, predictions of color discrimination performance are made for a deuteranope and protanope standard observer for each of three commercial color deficiency “treatment” filters. Five deuteranopes and five protanopes then participated in two experiments. They were asked to order the caps of the D-15 test, and in a second experiment arrange color pairs (from the D-15 test) in order of difference. Predictions and subject performance reveal that although X-Chrom aided dichromats gain both luminous and chromatic information, all dichromats used predominantly chromaticity information in discrimination tasks. The colorimetric tools correctly predicted that protanopes would derive less useful luminous information from the X-Chrom filter compared with deuteranopes, and correctly predicted an increase in discrimination of blues and purples for both classes of red-green color deficients.
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|
6. |
Effect of Luminance, Contrast, and Eccentricity on Visual Acuity in Senile Macular Degeneration |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 265-270
BRIAN BROWN,
KARLA ZADNIK,
IAN BAILEY,
Preview
|
PDF (446KB)
|
|
摘要:
We examined the effect of luminance on low contrast visual acuity in six patients with mild reductions in vision due to senile macular degeneration (SMD) and in six normals of approximately the same age. At the highest luminance tested the SMD patients showed a reduction in acuity compared to the controls, with eccentricity and contrast effects clearly shown, The SMD patients had difficulty performing the acuity task at the lower luminances (0.26 and 0.75 cd/m2); they showed little or no increase in visual acuity with increasing contrast levels at the lower luminances. Acuity was slightly influenced by target eccentricity at these luminances. These data suggest that the adaptation mechanisms allowing the normal visual system to operate efficiently over a wide range of luminances are affected in SMD, even when clinically measured acuity is only moderately depressed.
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|
7. |
Eyelid Closure Effects on the Refractive Error of the Eye in Dark‐and in Light‐Reared Kittens |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 271-273
U. YINON,
K. KOSLOWE,
Preview
|
PDF (232KB)
|
|
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|
8. |
An Optometric Purview of Intraorbital Meningioma |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 274-278
PAULA NEWSOME,
Preview
|
PDF (375KB)
|
|
摘要:
A 34-year-old black male presented with marked unilateral proptosis and pain in the left eye. Visual acuities were OD 6/7.5 (20/25) and OS 6/120 (20/400). His left eye was exophthalmic, had a Marcus Gunn pupil, and exposure keratitis. Sectorial pallor and a decreased Kestenbaum count were evident on the left optic nerve head. A tentative diagnosis of orbital meningioma was made and later confirmed. Optometric management of the patient, including appropriate screening tests and referrals, are discussed.
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|
9. |
Electric CataractA Rare Clinical Entity |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 279-283
SUSAN OLESZEWSKI,
JEFFREY NYMAN,
Preview
|
PDF (262KB)
|
|
摘要:
Bilateral crystalline lens opacities developed in a 39-year-old black male who had been involved in an electrical accident approximately 1 yr before our examination. The anterior subcapsular opacities had feathered edges and a slightly raised center. The typical appearance and progressive course of the opacities, as well as the history, led to the diagnosis of electric cataract.
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|
10. |
Effect of Luminance on Scotomas |
|
American Journal of Optometry and Physiological Optics,
Volume 61,
Issue 4,
1984,
Page 284-288
GEORGE WOO,
JOHN WESSEL,
C. KEMP,
Preview
|
PDF (337KB)
|
|
ISSN:0093-7002
出版商:OVID
年代:1984
数据来源: OVID
|