|
21. |
In vitro1H NMR “mapping” of human intervertebral discs |
|
Magnetic Resonance in Medicine,
Volume 3,
Issue 1,
1986,
Page 146-149
I. Furó,
M. Bobest,
I. Pócsik,
K. Tompa,
Preview
|
PDF (207KB)
|
|
摘要:
AbstractHuman intervertebral discs were investigated by1H NMRin vitro. The measured parameters of samples differently located in discs give the “maps” of discs. The spin‐lattice relaxation‐time maps show similar structure to dry matter and bound water maps, which might mean the future possibility to detect certain disc processes via accurateT1images. © 1986 Academic Pr
ISSN:0740-3194
DOI:10.1002/mrm.1910030122
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
22. |
Neurometabolic effects of an inborn error of amino acid metabolism demonstratedin vivoby1H NMR |
|
Magnetic Resonance in Medicine,
Volume 3,
Issue 1,
1986,
Page 150-156
David G. Gadian,
Edward Proctor,
Stephen R. Williams,
Ernest B. Cady,
R. Mark Gardiner,
Preview
|
PDF (408KB)
|
|
摘要:
AbstractThe elevated levels of brain histidine in histidinaemic mice are detectedin vivoby1H NMR at 8.5 and 1.9 T. The concentrations determined from thein vivospectra correlate well with subsequent analytical determinations. This technique is discussed in relation to monitoring phenylalaninc in humans with phenylketonuria. © 1986 Academic Press, Inc
ISSN:0740-3194
DOI:10.1002/mrm.1910030123
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
23. |
Elimination of coupling between cylindrical transmit coils and surface‐receive coils forin vivoNMR |
|
Magnetic Resonance in Medicine,
Volume 3,
Issue 1,
1986,
Page 157-163
M. Robin Bendall,
Alan Connelly,
Jamie M. McKendry,
Preview
|
PDF (538KB)
|
|
摘要:
AbstractCoupling between large transmit and surface‐receive coils is eliminated using a λ/4 cable, terminated with crossed diodes to ground, inserted between the receive coil and ground, and by using a cable of length a little less than λ/2 inserted between the transmit match capacitance and the normal crossed diodes in the transmit input line. © 1986 Academic Press,
ISSN:0740-3194
DOI:10.1002/mrm.1910030124
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
24. |
31P and23Na NMR studies of the structure and lability of the sodium shift reagent, bis(tripolyphosphate)dysprosium(iii) ([dy(p3O10)]7−) ion, and its decomposition in the presence of rat muscle |
|
Magnetic Resonance in Medicine,
Volume 3,
Issue 1,
1986,
Page 164-168
N. A. Matwiyoff,
C. Gasparovic,
R. Wenk,
J. D. Wicks,
A. Rath,
Preview
|
PDF (263KB)
|
|
摘要:
AbstractThe31P NMR of aqueous [Dy(P3O10)2]7−demonstrates that it is in slow exchange with P3O 105−on the NMR time scale. In the presence of tissue, [Dy(P3O10)2]7−decomposes to PO4with an accompanying slow change of the tissue23Na NMR of extracellular Na+ion in several NMR distinguishable extracellular sites. © 1986 Academic Pr
ISSN:0740-3194
DOI:10.1002/mrm.1910030125
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
25. |
Hypoxia‐sensitive NMR contrast agents |
|
Magnetic Resonance in Medicine,
Volume 3,
Issue 1,
1986,
Page 169-174
Harold M. Swartz,
Kai Chen,
Mark Pals,
Marjeta Sentjurc,
Philip D. Morse,
Preview
|
PDF (327KB)
|
|
摘要:
AbstractThe rate of reduction of nitroxides is shown to be more rapid in hypoxic cells. The rate of reduction and the effect of hypoxia on the reduction rate vary for different nitroxides. These findings indicate that it may be feasible to developin vivoNMR contrast agents that selectively will indicate areas of hypoxia and thereby aid in the detection of disease processes such as neoplasia, ischemia, and inflammation. © 1986 Academic Press, Inc
ISSN:0740-3194
DOI:10.1002/mrm.1910030126
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
26. |
Flow measurement by the development of phase differences during slice formation in mr imaging |
|
Magnetic Resonance in Medicine,
Volume 3,
Issue 1,
1986,
Page 175-179
I. R. Young,
G. M. Bydder,
J. A. Payne,
Preview
|
PDF (245KB)
|
|
摘要:
AbstractA method for measuring flow based on the shifting of the rephasing pulse following slice selection in partial saturation is described. The technique is based on a partial saturation sequence and retains much of the high signal which is a feature of the use of this sequence. Images obtained while encoding for the flow signal compared with those when not encoding appear very similar. © 1986 Academic Press, Inc
ISSN:0740-3194
DOI:10.1002/mrm.1910030127
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
27. |
Announcements of meetings |
|
Magnetic Resonance in Medicine,
Volume 3,
Issue 1,
1986,
Page 180-180
Preview
|
PDF (67KB)
|
|
ISSN:0740-3194
DOI:10.1002/mrm.1910030128
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
28. |
Masthead |
|
Magnetic Resonance in Medicine,
Volume 3,
Issue 1,
1986,
Page -
Preview
|
PDF (80KB)
|
|
ISSN:0740-3194
DOI:10.1002/mrm.1910030101
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1986
数据来源: WILEY
|
|