|
1. |
Truncation Artifacts in Magnetic Resonance Imaging |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page 517-526
Michael L. Wood,
R. Mark Henkelman,
Preview
|
PDF (640KB)
|
|
摘要:
AbstractA method has been developed to reduce a magnetic resonance image artifact arising from the Fourier transformation of data truncated in the phase‐encoding direction. The discontinuity is eliminated between the phase of the complex data sample associated with the maximum negative phase‐encoding gradient and the phase of the maximum positive gradient sample. Images retain sharper edges than if low‐pass filtering is employed. The method is demonstrated on clinical images, then an explanation of the method is presented.© 1985 Academic Pre
ISSN:0740-3194
DOI:10.1002/mrm.1910020602
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
2. |
Phase Alterations of Spin Echoes by Motion along Magnetic Field Gradients |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page 527-533
Richard E. Wendt III,
Paul H. Murphy,
Joseph J. Ford,
R. Nick Bryan,
John A. Burdine,
Preview
|
PDF (320KB)
|
|
摘要:
AbstractUsing a Taylor series expansion of the phase shift of a moving isochromatic spin group in the presence of a magnetic field gradient, the refocusing effects of the Carr‐Purcell‐Meiboom‐Gill pulse sequence on stationary nuclei and those with constant, rectilinear velocity are readily demonstrated. Continuing the analysis to higher orders of motion reveals that nuclei with a constant, rectilinear acceleration have a phase shift at the spin echoes which increases linearly with echo number. Constant, rectilinear jerk (the time rate of change of acceleration) leads to an increase in phase shift from echo to echo which is quadratic in nature with an overlying reduction of the odd‐numbered echoes by a constant amount. Motion parameters may be measured by parameter identification techniques. These principles may be applied to phase‐sensitive NMR imaging.© 1985 Academic
ISSN:0740-3194
DOI:10.1002/mrm.1910020603
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
3. |
Time‐Multiplexed Multislice Inversion‐Recovery Techniques for NMR Imaging |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page 534-539
H. W. Park,
M. H. Cho,
Z. H. Cho,
Preview
|
PDF (370KB)
|
|
摘要:
AbstractMultislice imaging techniques effectively applicable to inversion‐recovery (IR) imaging are developed and applied to human imaging. These new multislice IR imaging sequences employ the time‐multiplexing (TM) technique conventionally used in the slice‐by‐slice saturation‐recovery (SR) imaging. Two new time‐multiplexed multislice (TMM) IR imaging sequences are proposed and some of the experimental results obtained with the methods are presented.© 1985 Academ
ISSN:0740-3194
DOI:10.1002/mrm.1910020604
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
4. |
Vascular Occlusions Detected by Magnetic Resonance Imaging |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page 540-554
Peter L. Choyke,
Herbert Y. Kressel,
Leon Axel,
Warren Gefter,
David Thickman,
Peter H. Arger,
Steven G. Meranze,
Preview
|
PDF (954KB)
|
|
摘要:
AbstractEarly experience with magnetic resonance imaging (MRI) indicates that it is well suited as a noninvasive vascular imaging modality. Blood flow at physiologic velocities results in a low signal within the vessel lumen and this property allows the separation of flowing blood from surrounding soft tissues. While flow effects, aneurysms, and mural lesions have been emphasized in the literature, vascular occlusions have received less attention. We evaluated 21 patients with documented venous or arterial occlusions on a 0.12‐T developmental resistive unit. Venous occlusions caused by thrombus generally appeared as focal regions of increased signal. In 3 of 10 cases the venous thrombus itself could not be identified but the absence of a low‐signal lumen in a normal location confirmed the impression of thrombus. In 2 of 17 venous occlusions a rim of low signal was noted around the thrombus. Venous collaterals were commonly seen. Tumor thrombus tended to have signal characteristics similar to the main bulk of the tumor from which it arose. There were four arterial occlusions including two cases of emboli, one arteriosclerotic occlusion, and one case of tumor invasion. Vascular calcifications, clearly evident on plain radiographs, were not seen on MRI. MIR appears to be a potentially useful nonivasive means of detecting vascular occlusions.© 1985 Academic Press
ISSN:0740-3194
DOI:10.1002/mrm.1910020605
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
5. |
Magnetic Resonance Imaging the Velocity Vector Components of Fluid Flow |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page 555-566
David A. Feinberg,
Lawrence E. Crooks,
Phillip Sheldon,
John Hoenninger Iii,
Jeffrey Watts,
Mitsuaki Arakawa,
Preview
|
PDF (737KB)
|
|
摘要:
AbstractEncoding the Precession phase angle of proton nuclei for Fourier analysis has produced accurate measurement of fluid velocity vector components by MRI. A Pair of identical gradient pulses separated in time by exactly ½ TE, are used to linearly encode the phase of flow velocity vector components without changing the phase of stationary nuclei, Two‐dimensional Fourier transformation of signals gave velocity density images of laminar flow in angled tubes which were in agreement with the laws of vector addition. These Velocity profile images provide a quantitative method for the investigation of fluid dynamics and hemodynamics.© 1985 Academic Press,
ISSN:0740-3194
DOI:10.1002/mrm.1910020606
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
6. |
A Novel Double‐Surface Coil Approach to Phosphorus‐31 Spectroscopy: A Study of Hemispheric Brain Injury in the Rat |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page 567-575
Wil M. Chew,
Michael E. Moseley,
Merry C. Nishimura,
Takahiro Hashimoto,
Larry H. Pitts,
Thomas L. James,
Preview
|
PDF (482KB)
|
|
摘要:
AbstractAn arrangement of two surface coils was devised to allow phosphours‐31 (31P) NMR spectroscopy of a localized hemispheric brain injury model in the rat. Two elliptical (8×12mm) surface coils are placed parallel to each other (3 mm apart) over each side of the rat head. Spectra are collected from either the normal or the injured side of the head using the appropriate surface coil. A passive detuning method was used to eliminate unwanted coil‐coil interactions.31P imaging results with the two coils on phantoms show excellent isolation (6% signal overlap) between the two coils. The two‐coil set up was then used to follow a time course of injury from the hemispheric injury model.© 1985 Academic Pr
ISSN:0740-3194
DOI:10.1002/mrm.1910020607
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
7. |
Proton NMR Characteristics of a Biological System Useful for Developingin VivoSpectroscopy and Imaging Techniques for Tumors |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page 576-582
Ronald E. Block,
Barbara Parekh,
Rita Menditto,
Preview
|
PDF (402KB)
|
|
摘要:
AbstractA model system forin vivoproton NMR studies consisting of a transplantable tumor growing on a rat's tail was investigated at 90 MHz using a high‐resolution Fourier transform spectrometer. Spectra were obtained, relaxation times were measured, and the spatial distributions of proton signal intensities were estimated. We conclude that the model could be used for developing both spectroscopy and imaging approaches.© 1985 Academic Press,I
ISSN:0740-3194
DOI:10.1002/mrm.1910020608
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
8. |
A Method for Chemical‐Shift‐Selective Imaging |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page 583-585
Charles L. Dumoulin,
Preview
|
PDF (212KB)
|
|
摘要:
AbstractSelective suppression of a given resonance in an NMR image can be obtained with a π/2 pulse whose excitation spectrum in zero at the appropriate chemical shift. The selective π/2 pulse presented here is composed of two nonselective π/2 pulses of opposite phase. The two pulses are separated by a short interval which determines the excitation spectrum.© 1985 Academic Press,
ISSN:0740-3194
DOI:10.1002/mrm.1910020609
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
9. |
Detection of Exchange Reactions Involving Small Metabolite Pools Using NMR Magnetization Transfer Techniques: Relevance to Subcellular Compartmentation of Creatine Kinase |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page 586-594
Alan P. Koretsky,
Vladimir J. Basus,
Thomas L. James,
Melvin P. Klein,
Michael W. Weiner,
Preview
|
PDF (510KB)
|
|
ISSN:0740-3194
DOI:10.1002/mrm.1910020610
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
10. |
Masthead |
|
Magnetic Resonance in Medicine,
Volume 2,
Issue 6,
1985,
Page -
Preview
|
PDF (76KB)
|
|
ISSN:0740-3194
DOI:10.1002/mrm.1910020601
出版商:Wiley Subscription Services, Inc., A Wiley Company
年代:1985
数据来源: WILEY
|
|