1. |
Commentary: The Prevention of Sudden Infant Death Syndrome: Is There a Role for Home Monitoring? |
|
Journal of Medical Engineering&Technology,
Volume 9,
Issue 6,
1985,
Page 259-260
SouthallD. P.,
Preview
|
PDF (212KB)
|
|
摘要:
Although responsible for five deaths per day in the United Kingdom, the pathophysiology behind the Sudden Infant Death Syndrome (Sids) remains unknown. Not surprisingly, therefore, attempts have been made to prevent deaths by empirical methods. With the hypothesis that a cessation of breathing or a slowing of heart rate will occur prior to death from any cause, monitors to detect these changes have been developed and used on infants thought to be at increased risk of SIDS. The hypothesis presumes that by the time such changes are detected by the monitor there will be adequate time to resuscitate the infant without irreversible damage, and that infants at high risk of Sids can be identified.
ISSN:0309-1902
DOI:10.3109/03091908509032108
出版商:Taylor&Francis
年代:1985
数据来源: Taylor
|
2. |
Infant Respiration Monitoring—Evaluation of a Simple Home Monitor |
|
Journal of Medical Engineering&Technology,
Volume 9,
Issue 6,
1985,
Page 261-265
MunleyA. J.,
RailtonR.,
FisherJ.,
BarclayR. P. C.,
Preview
|
PDF (664KB)
|
|
摘要:
A new, inexpensive commercial infant respiration monitor, the Baby-sitter by Direct Diagnostics Ltd, has been evaluated and subjected to clinical trial. Dual respiration recordings were made from infants exhibiting apnoeic episodes to compare the new monitor with an acceptable reference monitor (Graesby Medical Model MR10). Both monitors are designed to detect respiration movement by means of pressure pulses produced in an air-filled sensor attached to the infant's abdomen. The new monitor is found to have unacceptable Performance.
ISSN:0309-1902
DOI:10.3109/03091908509032109
出版商:Taylor&Francis
年代:1985
数据来源: Taylor
|
3. |
A Case of Double Fracture in Total Hip Replacement |
|
Journal of Medical Engineering&Technology,
Volume 9,
Issue 6,
1985,
Page 266-269
BrowneAnthony O.,
SheehanJames M.,
Preview
|
PDF (1544KB)
|
|
摘要:
Femoral stem failure in total hip replacement is uncommon. It tends to occur predominantly in males over 1.8 m in height and over 76 kg in weight. Poor or inadequate cementing technique may lead to cement failure, which may be seen as roentgenographic lucencies present by as much as 12 months prior to actual stem failure. This article reports on a case of double stem failure, together with a full metallurgical examination, which indicated loosening of the implant prior to eventual failure from overload. Although one of the fractures occurred across an area of relative weakness in the stem material, this was not felt to be the principal cause of failure.
ISSN:0309-1902
DOI:10.3109/03091908509032110
出版商:Taylor&Francis
年代:1985
数据来源: Taylor
|
4. |
Design of a Computerized Device to Measure Simple Reaction Time/Decision Time |
|
Journal of Medical Engineering&Technology,
Volume 9,
Issue 6,
1985,
Page 270-276
ReppergerD. W.,
JacobsonJ.,
WalbroehlG. S.,
MichelN.,
GoodyearC.,
Preview
|
PDF (762KB)
|
|
摘要:
The construction and validation of a computerized device to test simple reaction time and decision-making time is dimmed. The device is required to demonstrate repeatability (consistency of response times from human subjects) across replications of the same experimental condition. A second requirement of the device is that it must separately and independently measure simple reaction time and the time it takes lo process one bit of information The concepts behind the construction of the box are discussed, as well ad the design of its internal circuits to achieve these specifications.
ISSN:0309-1902
DOI:10.3109/03091908509032111
出版商:Taylor&Francis
年代:1985
数据来源: Taylor
|
5. |
A Simple Rig for Stress Radiography of the Knee |
|
Journal of Medical Engineering&Technology,
Volume 9,
Issue 6,
1985,
Page 277-280
JacobsenKlaus,
IversenBjörn Franc,
Preview
|
PDF (653KB)
|
|
摘要:
A simple rig for obtaining stress radiographic measurements of the knee is presented. Lateral instability (varus), medial (valgus), anterior and posterior (drawer), as well as rotatory instability can be measured. The rig works by means of weights over pulleys, and the same forces are applied as when using a hydraulically-operated machine.The rig is small and inexpensive. A group of subjects showed values of stability within the same‘normal’area as those obtained with the hydraulically—operated stress machine.Data were processed on a microcomputer
ISSN:0309-1902
DOI:10.3109/03091908509032112
出版商:Taylor&Francis
年代:1985
数据来源: Taylor
|
6. |
Evaluation of Surgical Diathermy Units |
|
Journal of Medical Engineering&Technology,
Volume 9,
Issue 6,
1985,
Page 281-283
Preview
|
PDF (306KB)
|
|
摘要:
The evaluation of surgical diathermy units is being undertaken for the DHSS by the staff of the Bioengineering Unit at Cardiff Royal Infirmary.‘Health Equipment Information’No. 139, published in April 1985, contains evaluation reports on five surgical diathermy units, the Birtcher Hyfrecator 733-2, the Erbe Erbotom T71D, the KeyMed KBS-50, the Valleylab Surgistat, and the wolf. 2175. Summaries of the following, which have been the subject of previous evaluation reports and are still available are also included: Downs Diadon 170, Erbe Erbotom T175 and the Olympus PSD-2.The editors wish to acknowledge the help of the staff of the evaluation centre in the preparation of this edited version of‘HE1’139, particularly the contribution made by Dr D. G. Spendley.
ISSN:0309-1902
DOI:10.3109/03091908509032113
出版商:Taylor&Francis
年代:1985
数据来源: Taylor
|
7. |
Book Reviews |
|
Journal of Medical Engineering&Technology,
Volume 9,
Issue 6,
1985,
Page 286-288
Preview
|
PDF (374KB)
|
|
摘要:
A Thinker's Guide to Ultrasonic Imaging: By Raymond and Wendy Powis (Urban and Schwarzenberg. Baltimore, Munich, 1981: distributed in the UK by Pitman Publishing Ltd. London). pp. xiii + 417.£38.00.Current Perspectives in Health Computing: Edited by John Bryant arid Barbara Kostrewski (British Journal of Healthcare Computing, Weybridge, UK), pp 257.£9.50 (paperback). ISBN 0-948198-00-1.Biomaterials Science and Engineering: By Joon Bu Park (Plenum Press, New York and London, 1984), pp. 459.£35.00 ISBN 0-306-41689-1.
ISSN:0309-1902
DOI:10.3109/03091908509032114
出版商:Taylor&Francis
年代:1985
数据来源: Taylor
|
8. |
Books Received |
|
Journal of Medical Engineering&Technology,
Volume 9,
Issue 6,
1985,
Page 287-288
Preview
|
PDF (257KB)
|
|
摘要:
Neutron Contamination From Medical Electron Accelerators: NRCP Report No. 79(National Council on Radiation Protection and Measurements, 7910 Woodmount Avenue, Suite 1016, Bethesda, Maryland 20814–3095, USA, 1985).£14.00.Cybernetic Systems of Limb. Movements in man. Animals and Robotsby A. Morecki, J. Ekiel and K. Fidelium; translation editor. N. B Jones (Ellis Horwood Ltd. New York and Chichester, UK, 1985). pp. 242.£35.00 ISBN 0-85312-214-8.Mathematical Modelling of Dynamic Biological SystemsBy L. Finkelstein and E. R. Carson (Research Studies Press/John Wiley&Sons, Letchworth, UK/New York and Chichester, UK, 1985), pp. 355.£43.50. ISBN 0-86380-021-6/ 0-471-90688-3.Role of Informatics in Health Data Coding and Classification SystemsEdited by R. A. Côte, D.J. Protti and J. R. Schemer (North Holland-a division of Elsevier Science Publishers, Amsterdam, The Netherlands, 1985), pp. 394.£59.25/Dfl. 160.00. ISBN 0-444-87682-0.
ISSN:0309-1902
DOI:10.3109/03091908509032115
出版商:Taylor&Francis
年代:1985
数据来源: Taylor
|
9. |
New Products |
|
Journal of Medical Engineering&Technology,
Volume 9,
Issue 6,
1985,
Page 299-304
Preview
|
PDF (1447KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908509032116
出版商:Taylor&Francis
年代:1985
数据来源: Taylor
|
|