|
1. |
The development of a system for the evaluation of electromagnetic interference with pacemaker function: Hazards in the aircraft environment |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 161-165
Mc C. DellerAlastair G.,
ToffWilliam D.,
HobbsRobert A.,
RobbDavid J.,
CammA John,
Preview
|
PDF (1063KB)
|
|
摘要:
It has been recognized for many years that the electromagnetic (EM) environment within aircraft presents a potential hazard to the subject with a pacemaker. Most of the information currently available is, however, several years old and may not be strictly relevant to modern pacemakers and the electromagnetic environment found in today's civil aircraft [I and 2]. In mid 1986 it was therefore decided to investigate the effect on a number of currently available unipolar pacemakers of typical levels of electromagnetic interference encountered in civil aircraft.
ISSN:0309-1902
DOI:10.3109/03091908909044340
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
2. |
The prediction of drop size from intravenous infusion controllers |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 166-176
HillmanM. R.,
Preview
|
PDF (739KB)
|
|
摘要:
In intravenous therapy, gravity-fed drip controllers regulate the flow of fluid in terms of drops per minute, though the total amount of fluid to be in fused is specified in ml/h. To convert from one to the other it is regularly, erroneously, assumed that drop size is constant. The work described here investigates the relationship of drop size with respect to drip rate and fluid properties. The results are presented in an easy-to-use graphical form.
ISSN:0309-1902
DOI:10.3109/03091908909044341
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
3. |
Book Review |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 176-176
Preview
|
PDF (117KB)
|
|
摘要:
Doppler Echocardiography-The Quantitative Approach
ISSN:0309-1902
DOI:10.3109/03091908909044342
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
4. |
Infection control when servicing medical and laboratory equipment |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 177-180
CornerG. A.,
ShawA,
Preview
|
PDF (404KB)
|
|
摘要:
The risks of infection in servicing medical and hospital laboratory equipment are reviewed. Recommended procedures and precautions for dealing with these risks are detailed. These are based upon the practice adopted in the authors’own department. A‘permit to work’scheme is not felt to be universally applicable and the guiding criteria to judge any applied procedure are set down.
ISSN:0309-1902
DOI:10.3109/03091908909044343
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
5. |
Book review |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 180-180
Preview
|
PDF (106KB)
|
|
摘要:
Microcomputers in Medicine P. D. Coleridge-Smith and J. H. Scurr (Eds), Springer Verlag (G.B), 1988, 210 pages, 76 figs. Hard cover 120 DM. ISBN 3–540–19512–2.
ISSN:0309-1902
DOI:10.3109/03091908909044344
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
6. |
Automatic test equipment for rechargeable batteries |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 181-184
MarshallIan,
Preview
|
PDF (624KB)
|
|
摘要:
An automatic charger for the testing of a wide range of nickel cadmium and lead acid rechargeable batteries is described.
ISSN:0309-1902
DOI:10.3109/03091908909044345
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
7. |
Book review |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 184-184
Preview
|
PDF (96KB)
|
|
摘要:
Computing for Clinicians By Tim Chard. Elmore-Chard, London 1988, ISBN 0–9512981–0–0.
ISSN:0309-1902
DOI:10.3109/03091908909044346
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
8. |
Evaluation report: Dialysis equipment |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 185-188
Preview
|
PDF (281KB)
|
|
摘要:
As part of the continuing comparative evaluation programme of medical equipment sponsored by the UK Health Departments, the evaluation of dialysis equipment is being carried out within the University of Sheffield. Safety and performance assessments are carried out by the Department of Medical Physics and Clinical Engineering, and incorporate the results of testing by the Medical Equipment Laboratory of the British Standards Institution. User assessment was carried out in hospitals in the Sheffield Health Authority.The following is a review of Health Equipment Information (HEI) number 182, published in March 1988. It is the sixth in the series and contains evaluation reports on a further four haemodialysis systems. These are the Drake Willock 480, the Fresenius A1008D, and the Organon Teknika Redy 2000.The following is intended as a simple guide to choosing equipment suitable for haemodialysis, and may not take into account particular user requirements. Prospective purchasers are advised to refer to the ful1 published reports.Health Equipment Information is issued by the UK Department of Health, and is free to Health Service Personnel. Copies can also be purchased from: DH (Leaflets), PO Box 21, Stan more HA7 1AY, UK.
ISSN:0309-1902
DOI:10.3109/03091908909044347
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
9. |
Book review |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 190-190
MeldrumStuart J.,
Preview
|
PDF (96KB)
|
|
摘要:
Medical Device Register Published by Medical Device Register Inc., 655 Washington Blvd, Stamford, Connecticut 06901, USA. Volume 1: USA and Canada (1988). ISBN 0–942036–18–2.
ISSN:0309-1902
DOI:10.3109/03091908909044348
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
10. |
Contents pages |
|
Journal of Medical Engineering&Technology,
Volume 13,
Issue 3,
1989,
Page 191-196
Preview
|
PDF (631KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908909044349
出版商:Taylor&Francis
年代:1989
数据来源: Taylor
|
|