|
1. |
The bioengineer and the Finniston Report |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 57-58
SwansonS. A. V.,
SayersB. McA.,
Preview
|
PDF (286KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161091
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
2. |
Medical Telemetry |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 59-59
MatthewsP,
Preview
|
PDF (144KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161092
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
3. |
Ocular physiology |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 61-73
MellerioJ.,
Preview
|
PDF (2804KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161093
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
4. |
A microcomputer-based research system for the optical analysis of agar-cultured micro-organism colonies |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 74-80
JohnsonS.,
HarrisonL.,
PughA.,
O'gradyF.,
PearsonN.,
Preview
|
PDF (1452KB)
|
|
摘要:
A system which has been developed for the automatic measurement of agar-cultured microorganism colonies is described. A camera of the line-scanning type is used to scan the plates and details of the hardware and software development are explained. Flow diagrams are included which illustrate the operation of the system, but, as yet, no results are available. The prototype machine is undergoing evaluation testing.
ISSN:0309-1902
DOI:10.3109/03091908009161094
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
5. |
A microcomputer-based tachycardia termination system - a preliminary report |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 80-82
CammJ.,
WardD.,
GainsboroughJ.,
SpurrellR. A. J.,
Preview
|
PDF (281KB)
|
|
摘要:
A microprocessor-based pacing system is described which employs the autodecremental mode of atrial pacing. Preliminary experience suggests that this modality of pacing retains the advantages of rapid asynchronous atrial pacing but reduces the risk of provoking resistant atrial tachyarrhythmias. If the technique continues to prove successful it is suitable for incorporation into a fully implantable pacemaker.
ISSN:0309-1902
DOI:10.3109/03091908009161095
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
6. |
A hoist modification to allow a heavy tetraplegic patient in a swivel walker to be lifted |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 83-83
TaylorA. G.,
RoccaL.,
HeywoodP. J.,
Preview
|
PDF (267KB)
|
|
摘要:
The design of a hoist modification is described which allows a heavy tetraplegic patient to be put into a swivel walker and then lifted to the upright position with the aid of one person.
ISSN:0309-1902
DOI:10.3109/03091908009161096
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
7. |
Fourth World Ultrasound Congress |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 87-94
CosgroveD. O.,
Preview
|
PDF (1146KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161097
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
8. |
Books |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 94-95
TrotmanR. E.,
Preview
|
PDF (288KB)
|
|
摘要:
The Image and the Reality - A Case Study of the Impacts of Medical Technology.B. Stocking and S.L. Morrison, 1978, Oxford University Press, pp 80,£3.00. ISBN 0-19-721220-4Ion Selective intracellular microelectrodes. How to make and use them.R C Thomas, 1978, Academic Press London pp 109,£7.00 ISBN 0 12 688750 0
ISSN:0309-1902
DOI:10.3109/03091908009161098
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
9. |
News, Trends&Techniques |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 97-97
Preview
|
PDF (142KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161100
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
10. |
New Products |
|
Journal of Medical Engineering&Technology,
Volume 4,
Issue 2,
1980,
Page 99-99
Preview
|
PDF (394KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908009161101
出版商:Taylor&Francis
年代:1980
数据来源: Taylor
|
|