|
1. |
Medicine and Technology |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 109-111
PayneJ. P.,
Preview
|
PDF (1210KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091907809161774
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
2. |
Short Communications in the Journal of Medical Engineering and Technology |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 111-111
Preview
|
PDF (143KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091907809161775
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
3. |
Services to Bioengineering in the United Kingdom |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 115-124
TrotmanR. E.,
Preview
|
PDF (1220KB)
|
|
摘要:
In this paper, the resources available to the bioengineering profession are outlined. Information about the organisations that provide services to bioengineers, as well as indications as to how one might go about tapping them, is given.
ISSN:0309-1902
DOI:10.3109/03091907809161776
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
4. |
The Clinical Role of Thermography |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 125-138
CarterLinda M.,
Preview
|
PDF (1400KB)
|
|
摘要:
Although of established value in industrial and military usage, the potential of thermography as a clinical diagnostic technique has yet to be fully recognised. First used clinically in the diagnosis of breast disease, medical thermography has many other applications. These include the assessment of the severity of burn injuries and of tissue viability, the diagnosis of deep vein thrombosis, and of cutaneous malignant melanoma, the identification of carotid arterial disease, and of bone metastases, and the monitoring of drug therapy in rheumatology and in peripheral vascular disease. The suitability of thermography to the specific needs and problems in each of these clinical areas is outlined briefly, and the place of medical thermography in modern diagnostic imaging discussed.
ISSN:0309-1902
DOI:10.3109/03091907809161777
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
5. |
Discriminating Between Types of Pacemaker Lead Failure |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 130-135
HepburnF.,
Preview
|
PDF (1105KB)
|
|
摘要:
Damage to electrode leads in implanted cardiac pacemakers is commonly deduced from diminished and distorted stimulus artefacts. These changes may not occur and do not discriminate between fractured wire and ruptured insulation. Moreover, amplitudes vary from other causes and diagnosis from shape changes requires experience and oscilloscope equipment. The two types of lead damage cause opposite changes in the loading of the stimulus generator. For a few generators the stimulus duration and rate are load-sensitive, although the circuit is otherwise very stable, and simple measurement of these two temporal features can indicate and classify a failure, often in a latent stage before pacing failure has occurred.
ISSN:0309-1902
DOI:10.3109/03091907809161778
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
6. |
Medicine and Disability |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 136-138
OliverM.,
Preview
|
PDF (424KB)
|
|
摘要:
This paper identifies two distinct approaches to the treatment of disability, the medical and the social, and argues that up to now the medical approach has been dominant. Some of the defects of this approach are described and the implications of both approaches are spelled out.
ISSN:0309-1902
DOI:10.3109/03091907809161779
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
7. |
The Headlight |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 139-140
DuneNelson D.,
CôtéColette,
Preview
|
PDF (479KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091907809161780
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
8. |
The Use of a Steam Cleaning Lance to Clean Laboratory Equipment |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 140-141
TolleyG.,
Preview
|
PDF (500KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091907809161781
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
9. |
Safety and Performance of Medical Electrical Equipment |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 141-143
RichardsonN. H.,
Preview
|
PDF (423KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091907809161782
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
10. |
Books |
|
Journal of Medical Engineering&Technology,
Volume 2,
Issue 3,
1978,
Page 143-144
LeechGraham J.,
Preview
|
PDF (264KB)
|
|
摘要:
Practical EchocardiologyJos Roelandt, MD (Research Studies Press, Oregon, 1977) pp. xxiii + 306, US$19.95.Medid Gases-The Properties and UsesW. J. Grant (HM&M Publishers Ltd., Aylesbury, 1978) pp viii + 199,£4.00.£4.00.Computers in Ultrasonic DiagnosticsP. N. T. Wells and J. P. Woodcock (Research Studies Press. 1977) pp. xiv + 94. $14.95.
ISSN:0309-1902
DOI:10.3109/03091907809161783
出版商:Taylor&Francis
年代:1978
数据来源: Taylor
|
|