1. |
Continuous measurement of blood gases using a combined electrochemical and spectrophotometric sensor |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 5,
1994,
Page 165-168
VenkateshB.,
GluttonT. H.,
HendryS. P.,
Preview
|
PDF (438KB)
|
|
摘要:
The use of a combined electrochemical and fibreoptic continuous intra-arterial blood gas sensor is described. The purpose of the study was to evaluate the performance of the sensor in 10 patients in the intensive therapy unit following insertion through a femoral arterial cannula. To our knowledge this is the fast published study on the valuation of an intravascular blood gas sensor through a femoral arterial cannula. A total of 71 sets of data comparing the sensor with the blood gas analyser were obtained. The bias and precision for pH, Pco2and Po2were 0.006 and 0.07pH units, 0.2 and 1.65kPa (4.6% and 29%) and 0.8 and 2.7kPa (5.1 % and 14.3%) respectively. There was a degree of imprecision of the PCO2sensor, the reasons for which are discussed. In summary, the intra-arterial sensor functioned well when inserted into the femoral artery in post-cardiopulmonary bypass patients. There were no complications attributable to sensor placement.
ISSN:0309-1902
DOI:10.3109/03091909409030246
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
2. |
Hyomex: a miniature universal testing machine forin vivobiomechanical studies |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 5,
1994,
Page 169-172
HultE.,
EkstromL.,
HolmS.,
HanssonT.,
Preview
|
PDF (380KB)
|
|
摘要:
A miniaturized universal testing machine, HYOMEX, designed for biomechanically testing spinal structures of an anaesthetized research animal, such as a pig, is presented. A variety of mechanical applications such as static and dynamic tests, creep and relaxation tests, and fatigue tests with frequencies up to 20 Hz are possible. The system permits force control as well as displacement control. Continuous surveillance is made possible through interfacing the system to a computer. An application is presented where the viscoelastic behaviour in a porcine lumbar spine was measured.
ISSN:0309-1902
DOI:10.3109/03091909409030247
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
3. |
Waveform generator for electrical impedance tomography (EIT) using linear interpolation with multiplying D/A converters |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 5,
1994,
Page 173-178
BladB.,
JohannessonJ.,
JohnssonG.,
BachmanB.,
LindstromK.,
Preview
|
PDF (830KB)
|
|
摘要:
This paper describes the implementation of a multiplying digital-to-analogue (D/A) converter as a programmable waveform generator to be used in an electrical impedance tomography (EIT) system. Different digital techniques of generation waveforms are considered and the advantages and disadvantages of the chosen slope-plus-pedestal technique are presented. A wire-wrapped prototype system has been designed, and from measured frequency spectra the total harmonic distortion can be calculated to values between 1.1 and 2.9% depending on frequency.
ISSN:0309-1902
DOI:10.3109/03091909409030248
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
4. |
Comparison of oscillometric and intra-arterial blood pressure and pulse measurement |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 5,
1994,
Page 179-181
RithaliaS. V. S.,
EdwardsD.,
Preview
|
PDF (468KB)
|
|
摘要:
Non-invaswe oscillometric blood pressure and pulse measured by an Omron HEM-703CP monitor were compared with arterial values obtained from direct measurements of the radial artery. An excellent correlation and agreement was found between the two methods (systolic r=0.99; diastolic r=0.97; pulse r=0.99), although there was some variability among individual subjects. The range of difference between them was 0 to l. mmHg for systolic and—6 to + 5mmHg for diastolic pressures. When tested on the bench using the Metron QA-1280 non-invasive blood pressure analyser the HEM-703CP monitor rarely exhibited errors exceeding 2–3 mmHg over a measurement range of 50–200 mmHg.
ISSN:0309-1902
DOI:10.3109/03091909409030249
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
5. |
Selected contents |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 5,
1994,
Page 183-188
Preview
|
PDF (726KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909409030250
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
6. |
Book Reviews |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 5,
1994,
Page 189-193
Preview
|
PDF (526KB)
|
|
摘要:
Complications of Coronary AngioplastyBy A. Black, V. Anderson and S. G. Ellis. Marcel Dekker, New York, 1991, pp. 264. US $99.75. ISBN 0824784405.Chemical Sensor Technology, Vol. 2 Edited by T. Seiyama. Elsevier, Amsterdam, pp. 304. Dfl340.00, US $174.25. ISBN 0444987843.Medical Market Integration in the EECBy P. Evers. MDIS Publications Ltd, Chichester 1991, pp. 161. US$395.Ward's Anaesthetic Equipment, 3rd edn By A. Davey, J.T.B. Moyle and C.S. Ward. W.B. Saunders, London, 1992, pp. 391.£35. ISBN 0702014354.Evolution in Dialysis AdequacyEdited by V. Bonomini. 1993, SFr 198, pp. 196. Karger, Basel, ISBN 3805556837.Monitoring in AnesthesiaBy L. J. Saidman and N. T. Smith. Butterworth-Heinemann, London, 1993, L75.00, ISBN 0750609067Biomedical EngineeringBy A. E. Profio, 1993. 280pp. E49.50, Wiley, New York, ISBN 0471577685
ISSN:0309-1902
DOI:10.3109/03091909409030251
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
7. |
Evaluation |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 5,
1994,
Page 194-195
Preview
|
PDF (233KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909409030252
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
8. |
News, trends&techniques |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 5,
1994,
Page 196-199
Preview
|
PDF (420KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909409030253
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
9. |
New products |
|
Journal of Medical Engineering&Technology,
Volume 18,
Issue 5,
1994,
Page 200-203
Preview
|
PDF (1037KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909409030254
出版商:Taylor&Francis
年代:1994
数据来源: Taylor
|
|