|
1. |
Cardiovascular applications of biomaterials and implants–an overview |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 5,
1995,
Page 151-157
BlackM. M.,
Preview
|
PDF (659KB)
|
|
摘要:
This paper was originally commissioned by the UK Department of Health as a contribution to the work of its Biomaterials and Implants Research Advisory Group. This group was set up under the Chairmanship of Professor Sir Colin Berry with the following terms of reference: (i) to identify recent advances in the field of biomaterials; (ii) to consider the future contribution of biomaterials in improving human health; (Hi) to advise the Standing Group on Health Technology in areas where developments and assessment are needed; and (iv) to report to the Director of Research and Development (Professor Sir Michael Peckham) by October 1995. The cardiovascular field was one of several areas in biomaterials/implants considered by the Advisory Group. Amongst other areas considered were orthopaedics, dentistry, urology, wound repair and ophthalmology. Additionally, consideration was also given to such topics as chemical and biochemical sensors, drug release, hydrogels, membranes and artificial organs. The final report of the Advisory Group will be published at the end of this year. However, the Department has agreed that individual working papers such as the present one can be published independently in appropriate scientific journals.
ISSN:0309-1902
DOI:10.3109/03091909509009986
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
2. |
Noise coherence in closely-spaced electrodes: The implications for spatial averaged EGG recordings |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 5,
1995,
Page 158-161
TurnerI. N.,
WangW.,
EnglishM. J.,
VincentR.,
Preview
|
PDF (365KB)
|
|
摘要:
Ensemble signal averaging is conventionally used to reduce the noise content o/ECG recordings. One shortcoming of this technique is that it removes the possibility of registering transient signals. As a consequence the simultaneous averaging of spatially related leads has been used. This relies on the recording electrodes receiving correlated signal components for reinforcement together with uncorrelated noise. We have developed a methodology for studying EMG noise reduction by spatial averaging and present results for different electrode spacings which suggest minimum separations for noise rejection.
ISSN:0309-1902
DOI:10.3109/03091909509009987
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
3. |
An automated system for the functional evaluation of oscillometric non-invasive blood pressure monitors |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 5,
1995,
Page 162-176
GeakeW. B.,
AmooreJ. N.,
ScottD. H. T.,
Preview
|
PDF (1270KB)
|
|
摘要:
Most of the automated non-invasive blood pressure (NIBP) monitors in clinical use rely on the oscillometric technique for measuring the blood pressures. The functional evaluation of these monitors has relied on comparison with intra-arterial blood pressure measurements or comparison with‘standard’non-invasive blood pressure meters such as the Hawksley random zero sphygmomanometer. The commercial availability of simulated arm test instruments provides the opportunity for developing an alternative evaluation method. We describe the control of an NIBP simulator by a personal computer which is also linked to the NIBP monitor under test. An evaluation protocol is described and the data analysed to present graphically and in tabular form an assessment of the NIBP monitor.
ISSN:0309-1902
DOI:10.3109/03091909509009988
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
4. |
Selected contents |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 5,
1995,
Page 179-182
Preview
|
PDF (409KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909509009989
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
5. |
Book reviews |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 5,
1995,
Page 183-184
Preview
|
PDF (166KB)
|
|
摘要:
Szycher's Dictionary of Medical Devices Edited by Michael Szycher. Edited by Michael Szycher. Technomic Publishing Company (Lancaster, PA, USA). Price $75, ISBN 1-56676-275-8.Basic Ultrasound By Hylton B. Meire and Pat Farrant. By Hylton B. Meire and Pat Farrant. Wiley (1995), pp. 223. Price£24.95. ISBN 0 471 91691 9.Cell–based biosensors By J. Racek. By J. Racek (Technomic Publ. Co., USA, 1995), pp. 115. Price $45.00, ISBN
ISSN:0309-1902
DOI:10.3109/03091909509009990
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
6. |
News, trends&techniques |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 5,
1995,
Page 185-188
Preview
|
PDF (474KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909509009991
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
7. |
New products |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 5,
1995,
Page 189-190
Preview
|
PDF (351KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909509009992
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
|