1. |
Twenty-four hour ambulatory EEG monitoring: development and applications |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 229-238
PowellTheresa E.,
HardingG. F. A.,
Preview
|
PDF (1523KB)
|
|
摘要:
Since 1975 four-channel ambulatory monitoring has been available as a technique for prolonged EEG recording in an unrestricted environment. This increases EEG sampling time so that attacks can be recorded and enables the differentiation of epileptic and non-epileptic attacks. In recent years an eight-channel system has become available which provides greater scalp coverage and allows better localization of attacks and EEG abnormalities. Four-channel recording has been widely used to assess the efficacy of anticonvulsant medication in patients with absence seizures. It has also been used to investigate the effect of the environment on discharges, as well as any circadian variations in discharges. Ambulatory monitoring provides a useful alternative to sleep recording in the laboratory, both for the detection of abnormalities during sleep and for experimental sleep studies. Automated analysis techniques have so far been confined to the analysis of spike and wave activity and to the scoring of sleep stages.
ISSN:0309-1902
DOI:10.3109/03091908609022913
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
2. |
Recording of foetal movements: a comparison of three methods |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 239-247
ValentinL.,
MaršsálK.,
LindströmK.,
Preview
|
PDF (686KB)
|
|
摘要:
As decreased foetal movement (FM) may indicate impaired foetal health, FM recording has been suggested as a method of assessing foetal well-being. A non-intrusive, automated method of recording FM (FM-detector), was compared with maternal and ultrasonographic assessment ofFMs in 24 women in the third trimester of pregnancy. The FM-detector detected a greater proportion of ultrasonographically recorded FMs than the mothers did (median 70% and38%, respectively; p<0-001). Parity, gestational age, placental site or thickness, maternal weight or the distance from the maternal abdominal surface to the amniotic cavity did not affect the ability of the FM-detector to detect ultrasonographically recorded FMs. The estimation of FM strength by the FM-detector agreed fairly well with the assessment of FM strength by the ultrasound observer. The FM-detector would seem suitable for clinical use, as in the examination of pregnant women complaining of feeling‘less FM’.
ISSN:0309-1902
DOI:10.3109/03091908609022914
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
3. |
A power-assisted arm balancer |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 248-251
ThorpeT. E.,
Preview
|
PDF (1805KB)
|
|
摘要:
The design described in this paper arose from the need of a polio victim to be able to feed himself The patient was confined to a wheelchair. His right arm was completely paralysed, but he had limited ability to move his left arm. The arm balancer described allows the patient to swing his left arm freely in a horizontal plane, and also enables him to move his arm vertically, with power assistance under his own control.
ISSN:0309-1902
DOI:10.3109/03091908609022915
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
4. |
Technical note: Performance of 6 and 10 ampere appliance power couplers |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 252-254
ShawA.,
CraigD. M.,
SikM. J.,
Preview
|
PDF (933KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908609022916
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
5. |
A syringe pump tester |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 255-258
NiemanM.,
EvansA. L.,
ShawA.,
Preview
|
PDF (706KB)
|
|
摘要:
The equipment described allows the accuracy of a syringe pump to be tested quickly and conveniently. A digital micrometer assembly clips in place of the disposable syringe and transmits readings to a separate unit which displays flow rates in ml/h. Initial readings of pump output are given in 30 s, with readings to a higher accuracy within 4 min.
ISSN:0309-1902
DOI:10.3109/03091908609022917
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
6. |
An improved automatic tourniquet for regional analgesia |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 259-261
RichardsonW.,
ShawA.,
NiemanM.,
VennerR. H.,
Preview
|
PDF (352KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091908609022918
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
7. |
Evaluation report: Surgical diathermy units |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 262-266
Preview
|
PDF (385KB)
|
|
摘要:
‘Health Equipment Information’No. 153, published in May 1986, contains evaluation reports on a further four surgical diathermy units. These are the Esckmann TDB-50, the Fischer Bipolator, the Martin Elektrotom SOB and the Pyser Coa-Comp.Technical Assessment was carried out by the staff of the Bioengineering Unit at Cardiff Royal Infirmary and user assessment within Health Authorities in South Wales.For full details of the findings readers should consult‘HEI’153. The following is an extract prepared byDrD. G. Spendley, Senior Physicist at the Cardiff Evaluation Centre.
ISSN:0309-1902
DOI:10.3109/03091908609022919
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
8. |
Evaluation report: Resuscitators |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 267-278
Preview
|
PDF (991KB)
|
|
摘要:
As part of the continuing medical equipment evaluation programme sponsored by the UK Health Departments, the evaluation of resuscitators is being carried out in the Department of Anaesthetics, University of Wales College of Medicine, under the direction of Professor M. D. Vickers.‘Health Equipment Information’(HEI3) 152 is the second report on resuscitators, and contains detailed assessments of the following manually powered models, suitable for use with adults, and children over approximately three years of age or 10-15 kg body weight: Aga Revivator, Air-Viva 11, Ambu Mark 111, Flynn, Laerdal Silicone, Sohngen‘P’, New Sussex Basic and Universal, Vitalograph Rubber and Silicone, and Weinmann Combibag.For full details of the evaluation findings readers should consult HEP 152: the following are only extracts from the report. (‘HEI’is free to appropriate NHS staff, who should request copies from their Regional or District Administrator. Others can order the journal lcopy, cash with order] from DHSS [Leaflets], PO Box 21, Stanmore, Middlesex HA7 1AY, UK.)
ISSN:0309-1902
DOI:10.3109/03091908609022920
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
9. |
Evaluation report: Cardiotocographs |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 279-283
Preview
|
PDF (404KB)
|
|
摘要:
As part of the continuing comparative evaluation programme of electromedical equipment sponsored by the UK Health Departments, the evaluation of cardiotocographs is being carried out for the Department of Health and Social Security (DHSS) by the Bio-Medical Technology Group in the Department of Obstetrics and Gynaecology, St Mary's Hospital Medical School, London W2.The following report is based on extracts from‘Health Equipment Information’Number 156, published in July 1986 which contains evaluation reports on three further cardiotocographs. These are the Hewlett-Packard 8040A, the Huntleigh M2000 Mkll and the Kontron Fetasonde 5. The basis for inclusion in this evaluation was that each cardiotocograph has both internal and external modes of detecting foetal heart rate and uterine activity, and can be used for both intrapartum and antenatal monitoring.
ISSN:0309-1902
DOI:10.3109/03091908609022921
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
10. |
Book reviews |
|
Journal of Medical Engineering&Technology,
Volume 10,
Issue 5,
1986,
Page 286-288
MoseleyH.,
BarbenelJ. C.,
CusickGeoffrey,
PlanskoyBeate,
BowkerP.,
Preview
|
PDF (352KB)
|
|
摘要:
Laser Photobiology and Photo-medicineEdited by S. Martellucci and A. N. Chester (Plenum Press, New York and London, 1985), pp. 328. $55.00. ISBN 0-306-419 15-7.Introduction to Problem Solving in BiomechanicsC. von Heijne Wiktorin and M. Nordin (Lea&Febiger, Philadelphia, 1986), pp. 180. $31-25. ISBN 0-8 12 1-094 1-4.Biological Effects of UltrasoundEdited by W. L. Nyborg and M. C. Ziskin (Churchill Livingstone, New York, Edinburgh, London and Melbourne, 1985), pp. 187.£27.50. ISBN 0443-083 14-2.Radiotherapy Treatment Planning: Second EditionBy R. F. Mould (Adam Hilger Ltd, Bristol, UK, 1985), pp. 256.£19.50/ $29.00. ISBN 0-85274-788-8Frontiers in BiomechanicsEdited by G. W. Schmid-Schonbein, S. L-Y. Woo and B. W. Zweifach (Springer-Verlag, New York, Berlin, Heidelberg and Tokyo, 1986), pp. 398. ISBN 0-387-96 199-2.
ISSN:0309-1902
DOI:10.3109/03091908609022922
出版商:Taylor&Francis
年代:1986
数据来源: Taylor
|
|