1. |
Guest editorial |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 6,
1995,
Page 191-191
MeldrumStuart J.,
Preview
|
PDF (55KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909509030287
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
2. |
The origin and significance of secondary flows in the aortic arch |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 6,
1995,
Page 192-197
BlackM. M.,
HoseD. R.,
LawfordP. V.,
Preview
|
PDF (1199KB)
|
|
摘要:
This paper comprises a study of the secondary flow patterns that can develop in the human aortic arch. Clinical evidence of these secondary flows has been obtained by Kilneret al.using magnatic resonance velocity mapping techniques. Some of their results are presented for comparison in this present paper. Four different Parametrk models of the aortic arch have been analysed using computational fluid dynamic techniques. Both steady and transient flow conditions have been considered and two different commercially available software packages were used, namely FIDAP and FLOTRAN. A satisfactory comparison of the theoretical analysis with the results, bothin vivoandin vitro, obtained by Kilneret al.for their out-of-plane inlet model was found. The theoretical analysis can now be extended to anulyse the effect of different configurations and orientations of artificial aortic valves on the resulting aortic arch flow patterns.
ISSN:0309-1902
DOI:10.3109/03091909509030288
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
3. |
The application of an Actel field programmable gate array in the design of an ECG RR interval recorder |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 6,
1995,
Page 198-204
HarrisonA.,
HayesB. R.,
CroweJ. A.,
ChangS. T.,
Preview
|
PDF (808KB)
|
|
摘要:
Field Progammable Gate Arrays (FPGAs) allow dgtal circuitry to be integrated on to a single device without the long time penalty incurred with mask programmable Application Specific Integrated Circuits (ASICs). This makes FPAGA technology an attractive option to engineers involved in designing digital circuitry where space is at a premium. Furthermore, the relatively low cost qf FPGAs at low volume, compared to mask programmable ASICs make them an excellent prototyping option for designers who are considering low cost volume production with mask programmable ASICs. There are several different types of FPGA available which thus creates confusion for prospective users uncertain of their relative benefits. This paper serves as an introduction to FPGA technology and the stages involved in implementing a design, via the application of and Acterl FPGa to the development of an ambyulatory long term electrocardiogram (ECG) based RR interval recorder.
ISSN:0309-1902
DOI:10.3109/03091909509030289
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
4. |
The application of engineering and technology in the management of diabetes |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 6,
1995,
Page 205-210
ClaremontD. J.,
Preview
|
PDF (709KB)
|
|
摘要:
Diabetes mellitus is a relatively common disorder in which many of the body's systems are affected, resulting in morbidity and mortality. Early diaposis and good blood glucose control can delay or prevent the onset of these complications. This review illustrates how engineering and technology can help to achieve these goals.
ISSN:0309-1902
DOI:10.3109/03091909509030290
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
5. |
Scheduled inspection of electromedical equipment. Planning and assessment |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 6,
1995,
Page 211-218
AmooreJ. N.,
StayD. G.,
MatherJ.,
Preview
|
PDF (894KB)
|
|
摘要:
Scheduled inspections help ensure the safety and efficacy of medical equipment. To ensure the regular checking of all items we developed a practical and realizable protocol consisting of basic safety and functional tests. Non-productive time spent searching for equipment was reduced enlisting the help of ward stag Record keeping was simplified using monthly checklists detailing the tests to be performed. Clear labels distinguished items checked and the ward was informed about missing items. The effectiveness of the programme was assessed by auditing the number of items due for inspection, the average time per inspection, the number of faults found, and the incidence of breakdown repairs. The average inspection time per item was reduced to half an hour and the number of items due for inspection to below 10%. The programme was effective in fault detection (7% of items checked) and the incidence of breakdown repairs decreased from 75 to 53%.
ISSN:0309-1902
DOI:10.3109/03091909509030291
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
6. |
Selected contents |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 6,
1995,
Page 221-225
Preview
|
PDF (587KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909509030292
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
7. |
Book reviews |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 6,
1995,
Page 226-227
Preview
|
PDF (136KB)
|
|
摘要:
Advances in Materials Science and Implant Orthopedic Surgery, NATO Advanced Study InstitutesSeries E: Applied Sciences 294: Edited by R. Kossowsky and N. Kossovsky, Kluwer Academic Publishers, 1995, NLG 235, $74,£109, pp. 332. ISBN 0 7923 3558 9.Biomedical and Clinical InstrumentationBy R. Meltzer, (Interpharm Press Inc., USA, 1994), pp. 274. Price US $98.50. ISBN 0 935184 50 3Implantable Cardioverter-Defibrillator. A Comprehensive TextbookEdited by N. A. M. Estes 111, A. S. Manolis, and P. J. Wang (Marcel Dekker, Inc., New York, 1994), pp. 931. Price $195, ISBN 0-8247-9194-0
ISSN:0309-1902
DOI:10.3109/03091909509030293
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
8. |
News, trends&techniques |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 6,
1995,
Page 228-233
Preview
|
PDF (728KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909509030294
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
9. |
New Products |
|
Journal of Medical Engineering&Technology,
Volume 19,
Issue 6,
1995,
Page 234-236
Preview
|
PDF (892KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909509030295
出版商:Taylor&Francis
年代:1995
数据来源: Taylor
|
|