1. |
Designing special switches and control systems for multiply handicapped young people—a problem-led approach |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 87-91
ThornettC. E. E.,
Preview
|
PDF (889KB)
|
|
摘要:
This paper discusses a design strategy for assistive equipment for disabled people, in particular for special switches and control systems to enable the severely physically handicapped to control powered wheelchairs, computers, communication aids and environmental control systems. Special switch systems in this application must provide a complex human-equipment interface. Experience over a number of years with over 80 severely handicapped young people has refined the design strategy for both special switch systems and interfacing. Some examples are given of a problemled approach, and the materials used and the method of manufacture are discussed.
ISSN:0309-1902
DOI:10.3109/03091909009015419
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|
2. |
Biomechanical measurement of fracture healing |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 92-101
CunninghamJ. L.,
KenwrightJ.,
KershawC. J.,
Preview
|
PDF (1473KB)
|
|
摘要:
Three techniques for measuring fracture healing are presented. These techniques are: (1) use of strain gauge measurements of the forces in an external fixator to determine fracture stiffness, (2) measurement of the vibration modes of a fractured long bone compared to the unfractured contralateral and (3) comparison of the ultrasound velocity across the fracture site with that for the normal unfractured bone. Examples of clinical results obtained using these techniques are presented, and the advantages and disadvantages of each technique are discussed.
ISSN:0309-1902
DOI:10.3109/03091909009015420
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|
3. |
In vivocomparison of a twin wavelength laser Doppler flowmeter using He—Ne and laser diode sources |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 102-110
ObeidA. N.,
DoughertyG.,
PettingerS.,
Preview
|
PDF (807KB)
|
|
摘要:
This paper reports the results of a preliminaryin vivoinvestigation in which laser Doppler blood-flow measurements were made in a variety of tissues in the anaesthetized rat using a twin wavelength laser Doppler system. The aim was to assess whether there was any detectable difference in the depth response of the laser Doppler system to blood-flow in skin, muscle and brain tissue using red light (633 nm) from a He—Ne laser source and near infrared (NIR) light (780 nm) from a semiconductor diode laser source. The results show that under normalized conditions, the flow signals obtained from the near infrared laser Doppler system is consistently larger than that recorded from the red He—Ne laser Doppler system. This suggests that laser Doppler flowmetry systems based on NIR laser sources sample larger volumes of tissue than those based on red He—Ne lasers.
ISSN:0309-1902
DOI:10.3109/03091909009015421
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|
4. |
United States Government regulation of medical device software: a review |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 111-113
MurfittRobert R,
Preview
|
PDF (284KB)
|
|
摘要:
A brief history of the regulation of medical device software within the United States is presented, along with a discussion of the reasoning that the US Food and Drug Administration (FDA) presents for modifying the requirements for software regulation from those previously used for hardware devices. The current regulatory status is discussed for the two categories of medical device software, software used within medical devices and software used to produce or test medical devices. The published FDA documents which determine the current environment for the regulation of software are summarized and discussed. The two types of medical device software are related to the two areas of FDA regulation, good manufacturing practices and permission to sell medical devices. The expected direction of future medical device software regulation, and its relationship to the European Economic Community (EEC) and international markets is discussed.
ISSN:0309-1902
DOI:10.3109/03091909009015422
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|
5. |
Book reviews |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 114-114
SwansonS. A. V.,
Preview
|
PDF (117KB)
|
|
摘要:
Total Knee Replacement Edited by S. Niwa. J. P. Paul and S. Yamamoto, Springer Vcrlag, Japan. ISBN 70031-5. 288 pages. 1988.
ISSN:0309-1902
DOI:10.3109/03091909009015423
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|
6. |
Book reviews |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 115-115
GardenerJ. E.,
Preview
|
PDF (85KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909009015424
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|
7. |
TechAlert 2989-MET(M) Microcellular polymer foams for use as a biomaterial |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 118-119
Preview
|
PDF (208KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909009015425
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|
8. |
Content Pages |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 120-121
Preview
|
PDF (244KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909009015426
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|
9. |
News, trends&techniques |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 122-128
Preview
|
PDF (732KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909009015427
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|
10. |
New products |
|
Journal of Medical Engineering&Technology,
Volume 14,
Issue 3,
1990,
Page 129-132
Preview
|
PDF (436KB)
|
|
ISSN:0309-1902
DOI:10.3109/03091909009015428
出版商:Taylor&Francis
年代:1990
数据来源: Taylor
|